SiBE611027_A Indoor Unit
Removal Procedure 70
11 Remove the bearing.
12 Move the thermal
insulation slightly and
press the 2 hooks
undereath with a flat
screwdriver.
13 The figure shows the
appearance after
pressing the 2 hooks
(Appearance from rear
side).
You can see the
bottom of the vertical
blades ASSY is
detached from the
drain pan.
14 Unfasten the 3 hooks
(from front side) with a
flat screwdriver.
15 Remove the vertical
blades ASSY.
Step Procedure Points
Bearing
(R12752)
Thermal insulation
Drain pan
Bottom of vertical blades ASSY
(R12495)
(R12496)
(R12497)
Vertical blades ASSY