EasyManua.ls Logo

Daikin LREN8A7Y1B - User Manual

Daikin LREN8A7Y1B
156 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Installer and user reference guide
CO₂ ZEAS outdoor unit and capacity up unit
LREN8A7Y1B
LREN10A7Y1B
LREN12A7Y1B
LRNUN5A7Y1

Table of Contents

Other manuals for Daikin LREN8A7Y1B

Questions and Answers

Summary

About the documentation

About this document

Explains document structure, target audience, and available documentation.

General safety precautions

About the documentation

General information about the safety documentation.

Meaning of warnings and symbols

Explains hazard symbols, their meanings, and general safety icons.

For the installer

Safety advice specifically for installers.

General

General safety advice for installers.

Installation site

Critical safety requirements for installation locations.

Refrigerant - in case of R744

Safety procedures and precautions related to R744 refrigerant.

Electrical

Electrical safety precautions during installation and maintenance.

Specific installer safety instructions

General installation requirements

Key safety rules and regulations for installation.

About the box

Safety precautions during handling of the unit packaging.

About the unit and options

Safety related to unit components and accessories.

Unit installation

Safety guidelines specific to the unit installation process.

User safety instructions

General

Basic safety rules for unit operation.

Instructions for safe operation

Guidelines for safe and proper use of the unit.

About the system

System layout

Diagram showing system components and connections.

Operation

Operation modes

Describes the available operating modes.

Operation range

Specifies temperature limits for safe and effective operation.

Field piping pressure

Important pressure limits for field piping.

Energy saving and optimum operation

Maintenance and service

Maintenance before a long stop period

Procedures for preparing the unit for long-term storage.

Maintenance after a long stop period

Procedures for recommissioning the unit after storage.

About the refrigerant

Information about the refrigerant type and properties.

Recommended maintenance and inspection

Schedule and advice for regular maintenance and inspections.

Troubleshooting

Error codes: Overview

Lists and explains error codes for problem diagnosis.

Relocation

Disposal

About the box

Outdoor unit

Information about the outdoor unit packaging.

To transport the pallet

Instructions for safely moving the unit on its pallet.

To unpack the outdoor unit

Steps for removing the unit from its packaging.

To handle the outdoor unit

Safe handling procedures for the unit itself.

To remove the accessories from the outdoor unit

Identifying and removing included accessories.

About the units and options

Identification

How to identify the unit model.

Identification label: Outdoor unit

Details on the unit's identification label.

About the outdoor unit

General description of the outdoor unit.

Labels on outdoor unit

Explains various labels found on the outdoor unit.

System layout

Diagram of the overall system configuration.

Combining units and options

Information on compatible units and accessories.

Possible options for the outdoor unit

Details on available options for the outdoor unit.

Indoor unit constraints

Restrictions and limitations when connecting indoor units.

Unit installation

Preparing the installation site

Site preparation steps before unit placement.

Installation site requirements of the outdoor unit

Specific requirements for the outdoor unit's location.

Additional installation site requirements of the outdoor unit in cold climates

Special considerations for cold weather installations.

Additional installation site requirements for CO₂ refrigerant

Safety requirements specific to CO2 refrigerant.

Opening and closing the unit

Procedures for accessing internal components.

Mounting the outdoor unit

Steps for securely attaching the unit.

To provide the installation structure

Details on creating a stable mounting base.

To install the outdoor unit

Final steps for placing the unit on the structure.

To remove the transportation stay

Removing transport restraints.

Piping installation

Preparing refrigerant piping

Initial steps for refrigerant pipe setup.

Refrigerant piping requirements

Essential rules for refrigerant piping.

Refrigerant piping length and height difference

Limits on pipe run lengths and vertical differences.

Using stop valves and service ports

How to operate and use stop valves and service ports.

Connecting the refrigerant piping

Procedures for joining refrigerant pipes.

To cut off the spun pipe ends

Specific technique for preparing pipe ends.

To braze the pipe end

Brazing techniques for pipe connections.

Checking the refrigerant piping

Steps for ensuring pipe integrity and leak prevention.

Insulating the refrigerant piping

Importance and method of pipe insulation.

Electrical installation

About connecting the electrical wiring

Overview of electrical wiring connections.

Precautions when connecting the electrical wiring

Crucial safety steps for electrical work.

Field wiring: Overview

Diagram showing typical field wiring.

Guidelines when knocking out knockout holes

How to create openings for wiring.

Connections to the outdoor unit

Connecting wiring to the outdoor unit.

Low voltage wiring - Outdoor unit

Specifics for low voltage connections to the outdoor unit.

Charging refrigerant

About charging refrigerant

Introduction to the refrigerant charging process.

Precautions when charging refrigerant

Safety measures during refrigerant charging.

To determine the refrigerant amount

Calculating the correct refrigerant quantity.

To charge refrigerant

Step-by-step guide for charging refrigerant.

Finishing the outdoor unit installation

To check the insulation resistance of the compressor

Final check for compressor insulation resistance.

Configuration

Making field settings

How to configure system parameters.

To access the field setting components

Locating the field setting controls.

Field setting components

Description of DIP switches, buttons, and displays.

To set field settings

Detailed steps for setting parameters.

Commissioning

Overview: Commissioning

Introduction to the commissioning process.

Precautions when commissioning

Safety measures during commissioning.

Checklist before commissioning

Pre-commissioning checks.

To perform a test run (7-segment display)

Procedure for system test runs.

Hand-over to the user

Maintenance and service

Precautions for maintenance and service

General safety precautions for maintenance and service.

To prevent electrical hazards

Safety measures to avoid electrical shock during service.

To release refrigerant

Procedures for releasing refrigerant.

Troubleshooting

Precautions when troubleshooting

Safety advice before starting troubleshooting.

Solving problems based on error codes

How to resolve issues indicated by error codes.

Error codes: Overview

Detailed list of error codes and their causes/solutions.

Disposal

Technical data

Service space: Outdoor unit

Required clearance around the outdoor unit for maintenance.

Piping diagram: Outdoor unit

Schematic of the outdoor unit's piping.

Piping diagram: Capacity up unit

Schematic of the capacity up unit's piping.

Wiring diagram: Outdoor unit

Schematic of the outdoor unit's electrical wiring.

Glossary

Summary

About the documentation

About this document

Explains document structure, target audience, and available documentation.

General safety precautions

About the documentation

General information about the safety documentation.

Meaning of warnings and symbols

Explains hazard symbols, their meanings, and general safety icons.

For the installer

Safety advice specifically for installers.

General

General safety advice for installers.

Installation site

Critical safety requirements for installation locations.

Refrigerant - in case of R744

Safety procedures and precautions related to R744 refrigerant.

Electrical

Electrical safety precautions during installation and maintenance.

Specific installer safety instructions

General installation requirements

Key safety rules and regulations for installation.

About the box

Safety precautions during handling of the unit packaging.

About the unit and options

Safety related to unit components and accessories.

Unit installation

Safety guidelines specific to the unit installation process.

User safety instructions

General

Basic safety rules for unit operation.

Instructions for safe operation

Guidelines for safe and proper use of the unit.

About the system

System layout

Diagram showing system components and connections.

Operation

Operation modes

Describes the available operating modes.

Operation range

Specifies temperature limits for safe and effective operation.

Field piping pressure

Important pressure limits for field piping.

Energy saving and optimum operation

Maintenance and service

Maintenance before a long stop period

Procedures for preparing the unit for long-term storage.

Maintenance after a long stop period

Procedures for recommissioning the unit after storage.

About the refrigerant

Information about the refrigerant type and properties.

Recommended maintenance and inspection

Schedule and advice for regular maintenance and inspections.

Troubleshooting

Error codes: Overview

Lists and explains error codes for problem diagnosis.

Relocation

Disposal

About the box

Outdoor unit

Information about the outdoor unit packaging.

To transport the pallet

Instructions for safely moving the unit on its pallet.

To unpack the outdoor unit

Steps for removing the unit from its packaging.

To handle the outdoor unit

Safe handling procedures for the unit itself.

To remove the accessories from the outdoor unit

Identifying and removing included accessories.

About the units and options

Identification

How to identify the unit model.

Identification label: Outdoor unit

Details on the unit's identification label.

About the outdoor unit

General description of the outdoor unit.

Labels on outdoor unit

Explains various labels found on the outdoor unit.

System layout

Diagram of the overall system configuration.

Combining units and options

Information on compatible units and accessories.

Possible options for the outdoor unit

Details on available options for the outdoor unit.

Indoor unit constraints

Restrictions and limitations when connecting indoor units.

Unit installation

Preparing the installation site

Site preparation steps before unit placement.

Installation site requirements of the outdoor unit

Specific requirements for the outdoor unit's location.

Additional installation site requirements of the outdoor unit in cold climates

Special considerations for cold weather installations.

Additional installation site requirements for CO₂ refrigerant

Safety requirements specific to CO2 refrigerant.

Opening and closing the unit

Procedures for accessing internal components.

Mounting the outdoor unit

Steps for securely attaching the unit.

To provide the installation structure

Details on creating a stable mounting base.

To install the outdoor unit

Final steps for placing the unit on the structure.

To remove the transportation stay

Removing transport restraints.

Piping installation

Preparing refrigerant piping

Initial steps for refrigerant pipe setup.

Refrigerant piping requirements

Essential rules for refrigerant piping.

Refrigerant piping length and height difference

Limits on pipe run lengths and vertical differences.

Using stop valves and service ports

How to operate and use stop valves and service ports.

Connecting the refrigerant piping

Procedures for joining refrigerant pipes.

To cut off the spun pipe ends

Specific technique for preparing pipe ends.

To braze the pipe end

Brazing techniques for pipe connections.

Checking the refrigerant piping

Steps for ensuring pipe integrity and leak prevention.

Insulating the refrigerant piping

Importance and method of pipe insulation.

Electrical installation

About connecting the electrical wiring

Overview of electrical wiring connections.

Precautions when connecting the electrical wiring

Crucial safety steps for electrical work.

Field wiring: Overview

Diagram showing typical field wiring.

Guidelines when knocking out knockout holes

How to create openings for wiring.

Connections to the outdoor unit

Connecting wiring to the outdoor unit.

Low voltage wiring - Outdoor unit

Specifics for low voltage connections to the outdoor unit.

Charging refrigerant

About charging refrigerant

Introduction to the refrigerant charging process.

Precautions when charging refrigerant

Safety measures during refrigerant charging.

To determine the refrigerant amount

Calculating the correct refrigerant quantity.

To charge refrigerant

Step-by-step guide for charging refrigerant.

Finishing the outdoor unit installation

To check the insulation resistance of the compressor

Final check for compressor insulation resistance.

Configuration

Making field settings

How to configure system parameters.

To access the field setting components

Locating the field setting controls.

Field setting components

Description of DIP switches, buttons, and displays.

To set field settings

Detailed steps for setting parameters.

Commissioning

Overview: Commissioning

Introduction to the commissioning process.

Precautions when commissioning

Safety measures during commissioning.

Checklist before commissioning

Pre-commissioning checks.

To perform a test run (7-segment display)

Procedure for system test runs.

Hand-over to the user

Maintenance and service

Precautions for maintenance and service

General safety precautions for maintenance and service.

To prevent electrical hazards

Safety measures to avoid electrical shock during service.

To release refrigerant

Procedures for releasing refrigerant.

Troubleshooting

Precautions when troubleshooting

Safety advice before starting troubleshooting.

Solving problems based on error codes

How to resolve issues indicated by error codes.

Error codes: Overview

Detailed list of error codes and their causes/solutions.

Disposal

Technical data

Service space: Outdoor unit

Required clearance around the outdoor unit for maintenance.

Piping diagram: Outdoor unit

Schematic of the outdoor unit's piping.

Piping diagram: Capacity up unit

Schematic of the capacity up unit's piping.

Wiring diagram: Outdoor unit

Schematic of the outdoor unit's electrical wiring.

Glossary

Daikin LREN8A7Y1B Specifications

General IconGeneral
BrandDaikin
ModelLREN8A7Y1B
CategoryChiller
LanguageEnglish

Related product manuals