SiBE81-623A Troubleshooting
Photocatalytic Air Purifiers 31
6.2.2 Remote controller sends signals erratically.
1 Models Covered 5 Troubleshooting
MC707VM-S
MC707VM-W
Diagnosis Remedy
*Release child lock.
Replace battery.
Replace remote
controller.
Replace display
PCB.
Change installation
location.
2 Method of Mal-
function Detection
3 Malfunction Deci-
sion conditions
You can operate with ON/OFF
switch on the unit, but not with
remote controller.
4 Supposed Causes
Remote controller battery is
exhausted.
Remote controller is defective.
Display PCB is defective.
Malfunction is caused by inverter
fluorescent lamps.
Caution
Be sure to turn off power switch before connect or disconnect connector,
or parts damage may be occurred.
Is battery correct?
(2.5V or more?)
Is signal properly transmitted?
Check if infrared signal is
sent from remote control.
(Check with an infrared checker.)
No
No
Yes
Yes
Check remote controller for
normal operation.
Is there any inverter fluorescent
lamps around the unit?
No
Yes

Other manuals for Daikin MC707VM-W

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin MC707VM-W and is the answer not in the manual?

Daikin MC707VM-W Specifications

General IconGeneral
BrandDaikin
ModelMC707VM-W
CategoryAir Cleaner
LanguageEnglish

Related product manuals