General InformaTIon
This manual provides general information about the “F”
vintage Daikin Commercial Packaged Rooftop Unit model
MPS. In addition to an overall description of the unit, it
includes mechanical and electrical installation procedures,
commissioning procedures, sequence of operation information,
and maintenance instructions.
The MicroTech
®
III rooftop unit controller is available on
“F” vintage rooftop units. For a detailed description of the
MicroTech III components, input/output congurations, eld
wiring options and requirements, and service procedures,
see OM 920. For operation and information on using and
programming the MicroTech III unit controller, refer to the
appropriate operation manual (see Table 1).
For a description of operation and information on using
the keypad to view data and set parameters, refer to the
appropriate program-specic operation manual (see Table 1).
Table 1: Program Specic Unit Operation Literature
Rooftop unit control conguration Manual bulletin number
VFDs
OM 844 - MD2
OM 895 - MD3
OM 1190 - MD4
OM 1191 - MD5
OM 847 - MD6
MPS Unit Controller
Discharge Air Control (VAV or CAV)
Space Comfort Control (SCC)
OM 920
LonWorks Integration IM 918
BACnet Integration IM 917
BACnet IP Comm Module IM 916
Unit Nameplate
The unit nameplate is located on the outside of the main
control box door. It includes the unit model number, serial
number, electrical characteristics, and refrigerant charge.
Hazard Identication Information
DANGER
Dangers indicate a hazardous situation which will result in
death or serious injury if not avoided.
WARNING
Warnings indicate potentially hazardous situations, which can
result in property damage, severe personal injury, or death if
not avoided.
CAUTION
Cautions indicate potentially hazardous situations, which can
result in personal injury or equipment damage if not avoided.
Nomenclature (MPS 015050)
M P S015 – F G A
Daikin Packaged System
Nominal capacity (tons)
A = Standard DX Rows
B= Extra DX Rows
Heat medium
Y = None (cooling only)
G = Natural gas
E = Electric heat
W = Hot water heat
Design vintage
• 15F
• 20/26G
• 30–50 F
General InformaTIon
www.DaikinApplied.com 3 IM 1058-8 • MAVERICK II ROOFTOP SYSTEMS