3 | Components
Service manual
106
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
3.9.2 Repair procedures
To remove the indoor unit main PCB
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see "3.14Plate work"[4151].
1 Disconnect all connectors from the indoor unit main PCB.
2 Carefully click the indoor unit main PCB out of the PCB retainers.
aA
A Wall mounted indoor unit
a Indoor unit main PCB
aA
A Floor standing indoor unit
a Indoor unit main PCB