3 | Components
Service manual
177
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
a Screw (drain hose)
b Drain hose
c Swing raster motor cover
4 Remove the swing raster motor cover.
5 Disconnect the wiring harness from the swing raster motor.
6 Remove the swing flap motor wiring harness.
7 To install the swing flap motor wiring harness, see "Repair
procedures"[4199].
To install the swing flap motor wiring harness
1 Connect the wiring harness connector to the swing raster motor.
2 Install the swing raster motor cover.
a Screw (drain hose)
b Drain hose
c Swing raster motor cover
3 Install the drain hose on the indoor unit.
4 Install the drain hose fixation bracket. Install and tighten the screw.
5 Install the swing flap motor, see "Repair procedures"[4175].
Is the problem solved? Action
Yes No further actions required.
No Return to the troubleshooting of the