EasyManua.ls Logo

Daikin Perfera FVXM A Series - Page 184

Daikin Perfera FVXM A Series
256 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 | Components
Service manual
184
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
Class 50~71 indoor unit
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see "3.14Plate work"[4151].
1 Remove the switch box, see "3.14Plate work"[4151].
2 Put a small drain pan (or container) under the drain hose.
3 Remove the screw from the fixation bracket and pull the drain hose
downwards to remove it from the indoor unit.
ab
a Screw (drain hose)
b Drain hose
4 Remove the swing raster motor cover.
e
d
ca
bc
a Swing raster motor cover
b Swing raster motor assembly
c Screw (swing raster motor assembly)
d Fan guard
e Swing raster motor rod
5 Remove the 2 screws that fix the swing raster motor assembly to the indoor
unit.
6 Disconnect the swing raster motor rod from the swing raster shaft.
7 Remove the swing raster motor assembly from the indoor unit.
8 Remove the 2 screws that fix the swing raster motor to the bracket.

Table of Contents

Related product manuals