EasyManua.ls Logo

Daikin Perfera FVXM A Series - Page 58

Daikin Perfera FVXM A Series
256 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 | Components
Service manual
58
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
a
a Compressor wire terminals cover
3 Disconnect the Faston connectors from the compressor wire terminals U, V
and W.
INFORMATION
Note the position of the Faston connectors on the compressor wire terminals to
allow correct connection during installation.
V U
W
U Wire terminal U
V Wire terminal V
W Wire terminal W
4 Remove the compressor thermal protector, see "To remove the compressor
thermal protector"[468].
5 Remove the putty from the compressor accumulator. Keep for reuse.
6 Cut the compressor pipes (below the soldered joint) using a pipe cutter.