3 | Components
Service manual
82
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
a b
a Expansion valve pipe
b Expansion valve body
INFORMATION
The expansion valve and motor can have a different configuration / layout.
3 Remove the putty. Keep for re-use.
a bcA
a
aa
A Class 20~35 unit
a Putty
b Expansion valve pipe
c Expansion valve body
a bcA
A Class 42~71 unit
a Putty
b Expansion valve pipe
c Expansion valve body
4 Cut the expansion valve pipes using a pipe cutter.
5 Remove the expansion valve body.