3 | Components
Service manual
84
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
INFORMATION
The expansion valve and motor can have a different configuration / layout.
5 Reinstall the putty.
a bcA
a
aa
A Class 20~35 unit
a Putty
b Expansion valve pipe
c Expansion valve body
a bcA
A Class 42~71 unit
a Putty
b Expansion valve pipe
c Expansion valve body
6 Reinstall the putty.
7 To install the expansion valve motor, see "Repair procedures"[479].
8 Add refrigerant to the refrigerant circuit, see "Repair procedures"[4209].
To install the expansion valve motor with clip
1 Install the expansion valve motor on the expansion valve body.
INFORMATION
The expansion valve motor is equipped with a pipe retention clip. Install the pipe
retention clip over the pipe to lock the expansion valve motor.