ESIE17-08 | Part 3. Repair 3.3. Unit specific repair procedures
Page 78 15/11/18 | Version 1.1
R32 Sky-Air RZAG-M
Figure 3-13: Removing stop valve mounting plate
5. Cut the tie wrap that fixes the R2T thermistor wiring and put the R2T thermistor (2) aside.
6. Put aside the DC fan motor wiring.
7. Remove the terminal cover and unplug the compressor wiring (3).
8. Remove the rubber grommet (6) from the compressor.
9. Cut the compressor pipes (1) below the soldered joint.
10. Loosen and remove the 3 bolts (5) that fix the compressor (7).
11. Remove the compressor (7).
12. Remove the dampers (4) from the compressor (7).
13. Supply nitrogen to the piping circuit.
14. Heat the 2 compressor pipes (1) using an oxygen acetylene torch.
15. When the solder is liquid, remove the 2 compressor pipes (1).
16. Cut the nitrogen supply when the piping has cooled down.
1. Screw 3. Stop valve mounting plate
2. Screw