Installation and operation manual
VRV IV system air conditioner
English
Installation and operation
manual
VRV IV system air conditioner
REYQ8T7Y1B
REYQ10T7Y1B
REYQ12T7Y1B
REYQ14T7Y1B
REYQ16T7Y1B
REYQ18T7Y1B
REYQ20T7Y1B
REMQ5T7Y1B

Table of Contents

Questions and Answers

  • D
    danielleharrisSep 23, 2025
    How to fix Daikin REYQ8T7Y1B Air Conditioner ambient temperature sensor malfunction?
    • M
      Marcus ChavezSep 23, 2025
      If the ambient temperature sensor is malfunctioning on your Daikin Air Conditioner, check the connection on the PCB or actuator.
  • C
    christopherdeckerAug 23, 2025
    What to do if my Daikin REYQ8T7Y1B Air Conditioner shows a low pressure malfunction?
    • C
      christopher68Aug 25, 2025
      If your Daikin Air Conditioner is showing a low pressure malfunction, first open the stop valves. Then, check the refrigerant level and recharge the unit if needed. Finally, inspect the user interface display and the transmission wiring between the outdoor and indoor units.
  • J
    John HansonAug 25, 2025
    How to fix a Daikin REYQ8T7Y1B Air Conditioner indoor unit communication error?
    • J
      Joanne RoblesAug 26, 2025
      If you experience an indoor unit communication error with your Daikin Air Conditioner, check the user interface connection.
  • T
    Tina RaymondAug 27, 2025
    How to troubleshoot a Daikin REYQ8T7Y1B with an activated high pressure switch?
    • S
      Stephanie WeaverAug 27, 2025
      If the high pressure switch is activated on your Daikin Air Conditioner, check the stop valve situation and inspect for any abnormalities in the field piping or airflow over the air-cooled coil.
  • T
    Timothy WallaceAug 27, 2025
    What to do if my Daikin Air Conditioner has a refrigerant overcharge or stop valve closed?
    • M
      michaelconnerAug 27, 2025
      If your Daikin Air Conditioner indicates a refrigerant overcharge or a closed stop valve, check the refrigerant amount and recharge the unit if necessary. Also, ensure that the stop valves are open.
  • J
    joseph22Sep 17, 2025
    How to troubleshoot Daikin REYQ8T7Y1B electronic expansion valve (lower heat exchanger)?
    • T
      Theresa BrownSep 17, 2025
      If you are experiencing issues with the electronic expansion valve (lower heat exchanger) (Y3E) on your Daikin Air Conditioner, check the connection on the main PCB (X23A) or the actuator.
  • C
    Craig MurphySep 14, 2025
    How to troubleshoot Daikin Air Conditioner electronic expansion valve (receiver gas)?
    • K
      Kyle BowmanSep 14, 2025
      If you are experiencing issues with the electronic expansion valve (receiver gas) (Y4E) on your Daikin Air Conditioner, check the connection on the main PCB (X25A) or the actuator.
  • K
    kiarakennedySep 16, 2025
    How to troubleshoot Daikin REYQ8T7Y1B electronic expansion valve (subcool heat exchanger)?
    • J
      jordanguerreroSep 16, 2025
      If you are experiencing issues with the electronic expansion valve (subcool heat exchanger) (Y2E) on your Daikin Air Conditioner, check the connection on the main PCB (X22A) or the actuator.
  • G
    Gavin JenningsSep 6, 2025
    What to do if stop valve closed during Daikin REYQ8T7Y1B Air Conditioner system test run?
    • R
      richardjuarezSep 6, 2025
      If the stop valve is closed or wrong during the system test run of your Daikin Air Conditioner, open the stop valves.
  • A
    Alvin FreemanSep 3, 2025
    How to open a closed liquid stop valve on a Daikin REYQ8T7Y1B?
    • V
      Victoria ArmstrongSep 3, 2025
      If the liquid stop valve is closed on your Daikin Air Conditioner, open the liquid stop valve.

Summary

About the documentation

About this document

Details the documentation set, including safety, installation, and reference guides.

About the box

Accessory pipes: Diameters

Specifies the diameters of various accessory pipes used for system connections.

About the units and options

About the outdoor unit

Information on the VRV IV heat recovery system, its models, operating conditions, and system layout.

Preparation

Preparing the installation site

Guidelines for site selection, preparation, and cold climate considerations for outdoor units.

Preparing refrigerant piping

Requirements for refrigerant piping, including material, size selection, and branch kits.

Preparing electrical wiring

Safety device requirements for electrical wiring, including selection and sizing guidelines.

Installation

Opening the units

Instructions for opening outdoor units and their electrical component boxes.

Mounting the outdoor unit

Guidance on installing the outdoor unit level on a stable base, with foundation and height requirements.

Connecting the refrigerant piping

Procedures for routing and connecting refrigerant piping, including knockout holes and contamination protection.

Checking the refrigerant piping

Methods for performing leak tests and vacuum drying of the refrigerant piping system.

Charging refrigerant

Detailed procedures for charging refrigerant, including precautions, methods, and calculations.

Configuration

Making field settings

Overview of manual input for system configuration via PCB buttons and 7-segment displays.

To access mode 1 or 2

Explains accessing monitoring (Mode 1) and field settings (Mode 2) via push buttons.

Mode 1: Monitoring settings

Lists available monitoring settings and their descriptions, including power consumption and leak detection results.

Mode 2: Field settings

Lists available field settings and their descriptions, including target temperatures and height difference.

Commissioning

Precautions when commissioning

Safety guidelines for commissioning, emphasizing testing only after all preparations are complete.

Checklist before commissioning

Pre-commissioning checks for installation, wiring, and unit integrity.

About the test run

Description of the test operation procedure to verify system functionality and identify issues.

Technical data

Service space: Outdoor unit

Specifies minimum clearances around the outdoor unit for servicing and air inlet/outlet.

Piping diagram: Outdoor unit

Illustrates refrigerant piping diagrams for different HP configurations of the outdoor unit.

About the system

System layout

Overview of VRV IV heat recovery system models and their compatibility with indoor units.

Operation

Operation range

Recommended temperature and humidity ranges for safe and effective system operation.

Operating the system

Procedures for operating the system in cooling, heating, fan only, and automatic modes.

Using the dry program

Instructions for activating the dry program to reduce humidity with minimal cooling.

Maintenance and service

About the refrigerant

Information on refrigerant type, GWP, and precautions for handling and environmental impact.

Recommended maintenance and inspection

Guidance on regular maintenance and dealer-assisted inspections for optimal unit performance.

Troubleshooting

Solving problems based on error codes

Methods for resolving system issues by interpreting and addressing displayed malfunction codes.

Error codes: Overview

A comprehensive list of error codes, their causes, and solutions for troubleshooting.

Symptoms that are NOT system malfunctions

Descriptions of common operational behaviors that are not actual malfunctions.

Daikin REYQ8T7Y1B Specifications

General IconGeneral
BrandDaikin
ModelREYQ8T7Y1B
CategoryAir Conditioner
LanguageEnglish