Removal of Electrical Box / PCBs Si00-874
8 Removal Procedure
2. Remove the electrical box. [S80]: four way valve coil
1
Disconnect the
connector [S80].
2
Disconnect the
connector [S40].
[S40]: overload protector
3
Disconnect the
connector [S20].
[S20]: electronic expansion
valve coil
4
Disconnect the relay
connector for the
compressor.
Step
Procedure Points
(R7388)
[S80]
[S40]
(R7389)
[S20]
(R7390)
(R7392)