Removal of Electrical Box Si001156
12 Removal Procedure
4
Disconnect the relay
connector for the
compressor.
5
Disconnect the
connector for the
overload protector
[S40].
When reassembling,
connect the connectors in
the following order.
(1) [S40]
(2) relay connector for
compressor
(3) reactor
(4) [S20]
(5) [S80]
(6) [S70]
6
Cut the clamp.
Step Procedure Points
(R17478)
(R17479)
[S40]
(R11850)