Si001156 Removal of Compressor
Removal Procedure 29
3
Heat up the brazed part
of the suction side and
disconnect it.
Note:
Never use a metal saw to
cut pipes because the
sawdust may enter the
circuit.
When withdrawing the
pipes, be careful not to
pinch them firmly with pliers.
The pipes may get
deformed.
Provide a protective sheet or
a steel plate so that the
brazing flame cannot
influence peripheries.
Be careful so as not to burn
the compressor terminals,
the name plate, the heat
exchanger fins.
4
Lift the compressor up
and remove it.
Step Procedure Points
(R12032)
Suction side
(R7254)