EasyManuals Logo

Daikin RMX140JVMC8 User Manual

Daikin RMX140JVMC8
410 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #175 background imageLoading...
Page #175 background image
System control Si18-201
162 Main Functions
3.33 BP Unit Motorized Valve Control in High Discharge Pipe
Temperature
When the discharge pipe temperature exceeds a certain level during compressor operation, this
function opens the motorized valve to return the refrigerant to a low pressure level in order to
cool the compressor with refrigerant and lower the discharge temperature.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin RMX140JVMC8 and is the answer not in the manual?

Daikin RMX140JVMC8 Specifications

General IconGeneral
BrandDaikin
ModelRMX140JVMC8
CategoryHeat Pump
LanguageEnglish

Related product manuals