EasyManua.ls Logo

Daikin RN10FV1 - LED Indicator Lights

Daikin RN10FV1
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
28
TM-FT-0415-B
Normal Operation /
noitacidnI tluaF
Cool Mode
Auto mode in Cooling operation
Timer on
no edom peelS
no edom naF
no edom yrD
Room air sensor contact
Loose / Short
Call your dealer Blink E1
Outdoor coil sensor open Call your dealer Blink E3
Indoor coil sensor open Call your dealer Blink E2
Compressor overload /
Indoor coil sensor short / Call your dealer Blink E4
outdoor coil sensor short
noitarepo tsorfeD
5E knilBrelaed ruoy llaCkael saG
Hardware error (tact switch pin short) Call your dealer Blink E8
No feedback from indoor fan Call your dealer Blink E9
1 time
COOL
(GREEN)
Green
Red
1 time
3 times
3 times
4 times
2 times
6 times
Green
ON
ON or OFF
Blinking
LED Indicator Lights : Normal Operation And Fault Conditions For CoolingUnit
Error
Code
Action

Table of Contents