30
TM-FT-0415-B
Air Conditioner Unit Operation
In COOL, DRY and FAN mode
When stop
operation
Upper limit 55˚
Lower limit 85˚
Dry Mode
When the air humidity is high, the unit can operate in dry mode. Press <MODE> button and choose <DRY>.
If the room temperature is 2°C/3.6°F higher than the set temperature, the air conditioner will operate
under cooling mode until it reaches within the 2°C/3.6°F range of difference compared to the set
temperature before it converts to dry mode.
If the room temperature is within the 2°C/3.6°F range of difference compared to the set temperature,
it will directly operate under dry mode.
The unit will operate at LOW speed under dry mode.
Air Flow Control
For more effective air circulation, you can manually adjust the air discharge grille to the left or right.
During cool mode operation and dry mode operation, do not direct the air discharge louver down-
wards for too long. If operating continues in this way, condensation may occur on the louver, thus
resulting indrippings.
Frost Prevention
When the air filter is dirty, the evaporating temperature will decrease and eventually cause frosting.
If the evaporating temperature reaches -1°C/33.8°F, the unit will trip.
Fan Speed And Rated Cooling Capacity
The rated cooling capacity is provided at the high fan speed.
The cooling capacity is lower when the unit is operating at MEDIUM and LOW fan speed.
Notes On Flaps And Louvers Angles
When “SWING button” is selected, the flaps swinging range depends on the operation mode.
(See the figure.)
ATTENTION
Always use a remote controller to adjust the flaps angle. If you attempt to move it forcibly with hand
when it is swinging, the mechanism may be broken.
Be careful when adjusting the louvers. Inside the air outlet, a fan is rotating at a high speed.
Auto Random Re-start Function
If there is a power cut when the unit is operating, it will automatically resume the same operating mode
when the power is restored.