Specications (R22) - Continued
MODEL
INDOOR UNIT
WIRELESS
WIRED
OUTDOOR UNIT
l/s / CFM 321 / 680 453 / 960
dBA 45 49
mm/in
497 / 19.6543 / 21.4
mm/in 600 / 23.6700 / 27.6
mm/in 245 / 9.6 250 / 9.8
mm/in 535 / 21 596 / 23.51
mm/in 721 / 28.4803 / 31.6
mm/in 330 / 13 323 / 12.7
kg/lb 25 / 55 28 / 61.7
LIQUID
mm/in
6.35 / 1/4
GAS
mm/in
9.52 / 3/812.7 / 1/2
FLARE VALVE
UNIT
DIMENSION
HEIGHT
WIDTH
OUTDOOR UNIT
UNIT NET WEIGHT
PIPE
CONNECTION
TYPE
SIZE
WIDTH
PACKING
DIMENSION
DEPTH
DEPTH
HEIGHT
AIR FLOW
SOUND PRESSURE LEVEL
614 / 1300
5152
654 / 25.7
855 / 33.7
328 / 12.9
693 / 27.3
990 / 39.0
415 / 16.3
43 / 94.8
15.88 / 5/8
1) DUE TO OUR POLICY OF INNOVATION, ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO INTERNATIONAL STANDARDS SUCH AS ISO 5151 AND AHRI 210/240.
3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE MEASURED IN OYLM R&D SOUND ROOM. SOMEHOW DURING ACTUAL OPERATION, THE RESULT WILL BE HIGHER
AS A RESULT OF AMBIENT CONDITION.
mm/in
cm²/fl.oz
QUANTITY
355 / 14.0 401 / 15.8
DIAMETER
INDUCTION
QUANTITY
1
1
PROPELLER
MATERIAL
ASG20
DRIVE
DIRECT
FAN
TYPE
COMPRESSOR
TYPE
ROTARY
FAN MOTOR
TYPE
OIL AMOUNT
OIL TYPE
SUNISO-4GSI / FREOL-K56
330 / 11
350 / 11.8
32 74
0.17
0.33
18
30
6
751
860
SPEED
RPM
V/Ph/Hz
W
A
W
POWER SOURCE
RATED INPUT POWER
RATED RUNNING CURRENT
MOTOR OUTPUT
INSULATION GRADE
POLES
220 - 240 / 1 / 50