Outdoor Unit SiBE041134
8 Printed Circuit Board Connector Wiring Diagram
2. Outdoor Unit
Connectors and
Other Parts
PCB (1): Filter PCB
PCB (2): Main PCB
PCB (3): Forced Operation Button PCB
1) S11 Connector for main PCB
2) AC1, AC2, S Connector for terminal board
3) E1, E2 Terminal for ground wire
4) HL2, HN2 Connector for main PCB
5) HR1 Connector for reactor
6) FU1 Fuse (3.15 A, 250 V)
7) FU3 Fuse (20 A, 250 V)
8) V2, V3 Varistor
1) S10 Connector for filter PCB
2) S20 Connector for electronic expansion valve coil
3) S40 Connector for overload protector
4) S50 Connector for magnetic relay
5) S70 Connector for fan motor
6) S80 Connector for four way valve coil
7) S90 Connector for thermistors
(outdoor temperature, outdoor heat exchanger, discharge pipe)
8) S100 Connector for forced operation button PCB
9) HL3, HN3 Connector for filter PCB
10)HR2 Connector for reactor
11)U, V, W Connector for compressor
12)FU2 Fuse (3.15 A, 250 V)
13)LED A LED for service monitor (green)
14)V1 Varistor
15)J4 Jumper for facility setting
Refer to page 168 for detail.
16)J5 Jumper for improvement of defrost performance
Refer to page 169 for detail.
1) S110 Connector for main PCB
2) SW1 Forced cooling operation [ON/OFF] button
Refer to page 165 for detail.

Table of Contents

Other manuals for Daikin RXS20K3V1B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin RXS20K3V1B and is the answer not in the manual?

Daikin RXS20K3V1B Specifications

General IconGeneral
BrandDaikin
ModelRXS20K3V1B
CategoryAir Conditioner
LanguageEnglish

Related product manuals