SiBE041134 Main Functions
Function and Control 15
1.5 Program Dry Operation
Outline Program dry operation removes humidity while preventing the room temperature from lowering.
Since the microcomputer controls both the temperature and airflow rate, the temperature
adjustment and [FAN] setting buttons are inoperable.
Detail The microcomputer automatically sets the temperature and airflow rate. The difference between
the room thermistor temperature at start-up and the target temperature is divided into two
zones. Then, the unit operates in an appropriate capacity for each zone to maintain the
temperature and humidity at a comfortable level.
Room thermistor
temperature at start-up
Target temperature
X
Thermostat OFF point
Y
Thermostat ON point
Z
24ºC or more
Room thermistor
temperature at start-up
X
2.5ºC
X
0.5ºC
or
Y + 0.5ºC (zone B)
continues for 10 min.
23.5ºC
X
2.0ºC
X
0.5ºC
or
Y + 0.5ºC (zone B)
continues for 10 min.
~
18ºC
18ºC X
2.0ºC
X
0.5ºC = 17.5ºC
or
Y + 0.5ºC (zone B)
continues for 10 min.
17.5ºC
~
Zone A = Thermostat OFF
Y
+0.5ºC
Z
X
Zone B
Zone B
Zone C = Thermostat ON
(R11581)

Table of Contents

Other manuals for Daikin RXS20K3V1B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin RXS20K3V1B and is the answer not in the manual?

Daikin RXS20K3V1B Specifications

General IconGeneral
BrandDaikin
ModelRXS20K3V1B
CategoryAir Conditioner
LanguageEnglish

Related product manuals