231 Removal Procedure
4.5 Removal of Sound Blankets / Thermistors
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure Points
1
Remove the sound
blanket (back).
2
Remove the sound
blanket (outer).
Since the piping ports are
torn easily, remove the
sound blanket carefully.
3
Remove the sound
blanket (top upper).
Sound blanket
(back)
(R5293)
Sound blanket
(outer)
(R5294)
Sound blanket
(top upper)

Table of Contents

Other manuals for Daikin RXS50J2V1B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin RXS50J2V1B and is the answer not in the manual?

Daikin RXS50J2V1B Specifications

General IconGeneral
Outdoor unit weight48000 g
Outdoor units quantity1
Outdoor unit noise level48 dB
Outdoor unit dimensions (WxDxH)825 x 300 x 735 mm
TypeAir conditioner outdoor unit
Compressor typeRotary
Thermostat range- °C
Hose length (max)20 m
Refrigerating mediumR410A
Cooling capacity (max)- BTU/h
Air conditioner functionscooling, heating
Cooling capacity in watts (max)5000 W
Heating capacity in watts (max)6000 W
Cooling energy efficiency (EER, W/W)3.55
Heating energy efficiency (COP, W/W)3.7
Cooling airflow (indoor unit)2934 m³/h
Heating airflow (indoor unit)2586 m³/h
Power requirements220-240V, 50Hz
Annual energy consumption705 kWh