EasyManuals Logo

Daikin RXS50J2V1B User Manual

Daikin RXS50J2V1B
268 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #264 background imageLoading...
Page #264 background image
Piping Diagrams SiBE041101
253 Appendix
RXS42J2V1B
RXS50J2V1B
FIELD PIPING
9.5CuT
4.8CuT
4.8CuT
6.4CuT
MUFFLER
9.5CuT
PROPELLER FAN
7.9CuT
7.9CuT
9.5CuT
6.4CuT
ACCUMULATOR
MUFFLER
7.9CuT
COOLING
HEAT EXCHANGER
FIELD PIPING
6.4CuT
9.5CuT
OUTDOOR UNIT
12.7CuT
(6.4CuT)
REFRIGERANT FLOW
9.5CuT
HEATING
(9.5CuT)
7.9CuT
COMPRESSOR
M
φ.4.0×ID. 2.0CuT
OUTDOOR TEMPERATURE
THERMISTOR
HEAT EXCHANGER
THERMISTOR
MOTOR OPERATED
VALVE
MUFFLER
WITH
FILTER
MUFFLER
WITH
FILTER
MUFFLER
WITH
FILTER
LIQUID STOP
VALVE
GAS STOP
VALVE
FOUR WAY
VALVE
ON:HEATING
DISCHARGE PIPE
THERMISTOR
3D059590B
OUTDOOR UNIT
12.7CuT
12.7CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
7.9CuT
PROPELLER FAN
MUFFLER
HEAT EXCHANGER
7.9CuT
7.9CuT
M
COMPRESSOR
12.7CuT
12.7CuT
7.9CuT
7.9CuT
4.0CuT
4.0CuT
CAPILLARY TUBE 4
CAPILLARY TUBE 1
9.5CuT
MUFFLER
9.5CuT
6.4CuT
12.7CuT
6.4CuT
6.4CuT 6.4CuT
6.4CuT
FILTER
RECEIVER
FIELD PIPING
FIELD PIPING
REFRIGERANT FLOW
(12.7 CuT)
(6.4 CuT)
HEATING
COOLING
4.0CuT
4.0CuT
7.9CuT
MUFFLER
MUFFLER
WITH
FILTER
MOTOR OPERATED
VALVE
LIQUID
STOP VALVE
GAS STOP VALVE
WITH SERVICE PORT
FOUR WAY
VALVE
ON : HEATING
DISCHARGE PIPE
THERMISTOR
HEAT
EXCHANGER
THERMISTOR
CAPILLARY TUBE 2
CAPILLARY TUBE 3
OUTDOOR AIR TEMPERATURE
THERMISTOR
3D051637S

Table of Contents

Other manuals for Daikin RXS50J2V1B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin RXS50J2V1B and is the answer not in the manual?

Daikin RXS50J2V1B Specifications

General IconGeneral
Outdoor unit weight48000 g
Outdoor units quantity1
Outdoor unit noise level48 dB
Outdoor unit dimensions (WxDxH)825 x 300 x 735 mm
TypeAir conditioner outdoor unit
Compressor typeRotary
Thermostat range- °C
Hose length (max)20 m
Refrigerating mediumR410A
Cooling capacity (max)- BTU/h
Air conditioner functionscooling, heating
Cooling capacity in watts (max)5000 W
Heating capacity in watts (max)6000 W
Cooling energy efficiency (EER, W/W)3.55
Heating energy efficiency (COP, W/W)3.7
Cooling airflow (indoor unit)2934 m³/h
Heating airflow (indoor unit)2586 m³/h
Power requirements220-240V, 50Hz
Annual energy consumption705 kWh