iii Table of Contents
Part 5 Operation Manual ............................................................. 49
1. System Configuration............................................................................50
2. Operation Manual..................................................................................51
2.1 Remote Controller ..................................................................................51
2.2 AUTO · DRY · COOL · HEAT · FAN Operation ......................................52
2.3 Adjusting the Airflow Direction................................................................54
2.4 COMFORT AIRFLOW and INTELLIGENT EYE Operation....................56
2.5 POWERFUL Operation ..........................................................................60
2.6 OUTDOOR UNIT QUIET Operation.......................................................61
2.7 ECONO Operation .................................................................................62
2.8 OFF TIMER Operation ...........................................................................63
2.9 ON TIMER Operation .............................................................................64
2.10 WEEKLY TIMER Operation ...................................................................65
Part 6 Service Diagnosis............................................................. 73
1. Troubleshooting with LED .....................................................................75
1.1 Indoor Unit..............................................................................................75
1.2 Outdoor Unit ...........................................................................................75
2. Problem Symptoms and Measures .......................................................76
3. Service Check Function ........................................................................77
3.1 ARC452 Series.......................................................................................77
4. Troubleshooting ....................................................................................80
4.1 Error Codes and Description ..................................................................80
4.2 Indoor Unit PCB Abnormality .................................................................81
4.3 Freeze-up Protection Control or Heating Peak-cut Control....................82
4.4 Fan Motor (DC Motor) or Related Abnormality.......................................84
4.5 Thermistor or Related Abnormality (Indoor Unit)....................................86
4.6 Signal Transmission Error (between Indoor Unit and Outdoor Unit) ......87
4.7 Unspecified Voltage (between Indoor Unit and Outdoor Unit) ...............88
4.8 Outdoor Unit PCB Abnormality...............................................................89
4.9 OL Activation (Compressor Overload) ...................................................92
4.10 Compressor Lock ...................................................................................93
4.11 DC Fan Lock ..........................................................................................94
4.12 Input Overcurrent Detection ...................................................................95
4.13 Four Way Valve Abnormality..................................................................96
4.14 Discharge Pipe Temperature Control.....................................................98
4.15 High Pressure Control in Cooling .........................................................100
4.16 Compressor System Sensor Abnormality ............................................101
4.17 Position Sensor Abnormality ................................................................103
4.18 DC Voltage / Current Sensor Abnormality (20/25/35/42 Class) ...........106
4.19 CT or Related Abnormality (50 Class)..................................................107
4.20 Thermistor or Related Abnormality (Outdoor Unit)...............................109
4.21 Electrical Box Temperature Rise..........................................................111
4.22 Radiation Fin Temperature Rise ..........................................................113
4.23 Output Overcurrent Detection ..............................................................115
4.24 Refrigerant Shortage ............................................................................117
4.25 Low-voltage Detection or Over-voltage Detection................................120
4.26 Signal Transmission Error on Outdoor Unit PCB (50 Class Only) .......122
5. Check ..................................................................................................123
5.1 Fan Motor Connector Output Check ....................................................123

Table of Contents

Other manuals for Daikin RXS50J2V1B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin RXS50J2V1B and is the answer not in the manual?

Daikin RXS50J2V1B Specifications

General IconGeneral
Outdoor unit weight48000 g
Outdoor units quantity1
Outdoor unit noise level48 dB
Outdoor unit dimensions (WxDxH)825 x 300 x 735 mm
TypeAir conditioner outdoor unit
Compressor typeRotary
Thermostat range- °C
Hose length (max)20 m
Refrigerating mediumR410A
Cooling capacity (max)- BTU/h
Air conditioner functionscooling, heating
Cooling capacity in watts (max)5000 W
Heating capacity in watts (max)6000 W
Cooling energy efficiency (EER, W/W)3.55
Heating energy efficiency (COP, W/W)3.7
Cooling airflow (indoor unit)2934 m³/h
Heating airflow (indoor unit)2586 m³/h
Power requirements220-240V, 50Hz
Annual energy consumption705 kWh