Installer and user reference guide
Split packaged air-cooled water chiller
English
Installer and user
reference guide
Split packaged air-cooled water chiller
SERHQ020BAW1
SERHQ032BAW1
SEHVX20BAW
SEHVX32BAW
SEHVX40BAW
SEHVX64BAW

Table of Contents

Other manuals for Daikin SEHVX20BAW

Questions and Answers

  • S
    Stephen FloresAug 26, 2025
    How to fix high pressure error (SENPH/S1PH) on Daikin SEHVX20BAW Chiller?
    • C
      Chelsey BondAug 26, 2025
      If the Daikin Chiller displays a high pressure error (SENPH/S1PH), check that the circuit does not contain any air, ensure that water flow is possible by opening all valves, verify the water filter is not blocked, and confirm all refrigerant stop valves are open. For further assistance, contact your local dealer.
  • M
    Melissa ChavezAug 26, 2025
    How to fix refrigerant overcharge in Daikin SEHVX20BAW Chiller?
    • K
      kelly92Aug 27, 2025
      If your Daikin Chiller is experiencing a refrigerant overcharge, recalculate the required amount of refrigerant based on the piping length and correct the refrigerant charge level by recovering any excessive refrigerant using a refrigerant recovery machine.
  • M
    marcusramosAug 27, 2025
    What to do if Daikin SEHVX20BAW Chiller charging aborted?
    • W
      wrightchristopherAug 27, 2025
      If the Daikin Chiller displays 'Charging aborted', immediately close valve A. Then, check if the gas side stop valve and the valve of the refrigerant tank are open, and ensure the air inlet and outlet of the indoor unit are not obstructed. Correct any abnormalities and restart the automatic charging procedure.
  • R
    Raymond MitchellAug 27, 2025
    What to do if Daikin SEHVX20BAW has insufficient refrigerant?
    • M
      Maurice StevensAug 28, 2025
      If you suspect insufficient refrigerant in your Daikin Chiller, check if the additional refrigerant charge has been completed correctly. Recalculate the required amount of refrigerant from the piping length and add an adequate amount of refrigerant.
  • A
    Angel PayneAug 28, 2025
    What if piping and wiring of indoor unit are not correctly connected to the outdoor unit of Daikin Chiller?
    • C
      Connie ArmstrongAug 28, 2025
      If the piping and wiring of the specified indoor unit are not correctly connected to the outdoor unit of your Daikin Chiller, confirm that they are properly connected.
  • M
    Michele WilliamsAug 29, 2025
    What to do if Daikin Chiller displays recharge operation?
    • G
      grahamsarahAug 29, 2025
      If the Daikin Chiller displays 'Recharge operation', immediately close valve A and press the TEST OPERATION button once. The operation will restart from the charging mode judgement onwards.
  • T
    thompsonsarahAug 30, 2025
    How to troubleshoot R410A expansion valve error (K11E/K12E) on Daikin SEHVX20BAW Chiller?
    • H
      Hannah DavisAug 30, 2025
      If your Daikin Chiller is showing a R410A expansion valve error (K11E/K12E), check wiring connections. For further assistance, contact your local dealer.
  • S
    Sean DayAug 23, 2025
    What to do if Daikin SEHVX20BAW Chiller shows reversed power supply phase malfunction?
    • J
      Jennifer MyersAug 23, 2025
      If your Daikin Chiller displays a reversed power supply phase malfunction, correct the phase order.
  • M
    Megan RhodesSep 1, 2025
    How to troubleshoot returning water thermistor error (R12T/R22T) on Daikin Chiller?
    • J
      Janice BruceSep 1, 2025
      If your Daikin Chiller displays a returning water thermistor error (R12T/R22T), check wiring connections. For further assistance, contact your local dealer.
  • R
    robert41Sep 2, 2025
    How to fix R410A suction thermistor error (R14T/R24T) on Daikin SEHVX20BAW?
    • K
      kimberly98Sep 2, 2025
      If your Daikin Chiller displays a R410A suction thermistor error (R14T/R24T), check wiring connections. For further assistance, contact your local dealer.

Daikin SEHVX20BAW Specifications

General IconGeneral
ModelSEHVX20BAW
TypeAir Cooled Chiller
Cooling Capacity20 kW
RefrigerantR-410A
EER3.1
Power Supply400V, 3 Phase, 50Hz