13
INSTALLER’S INSTRUCTIONS
RELEASE 7.03
-
-
-
-
R
E
L
A
Y
- 3
-
-
-
-
-
-
-
-
-
- - -
O
F
F
-
-
-
-
-
-
By pressing OK, OFF becomes ON and the heating elements of the boiler start working. By pressing OK
again you go back to the OFF status
By pressing you go to R4= solenoid valve of the boiler autolevel
-
-
-
-
R
E
L
A
Y
- 4
-
-
-
-
-
-
-
-
-
- - -
O
F
F
-
-
-
-
-
-
By pressing OK, OFF becomes ON and the autolevel solenoid valve starts working. By pressing OK
again you go back to the OFF status
By pressing you go to R4= solenoid valve of group 1
-
-
-
-
R
E
L
A
Y
- 5
-
-
-
-
-
-
-
-
-
- - -
O
F
F
-
-
-
-
-
-
By pressing OK, OFF becomes ON and the solenoid valve of group 1 starts working. By pressing OK
again you go back to the OFF status R6= group 2,R7= group 3,R8= group 4
By pressing you go to R4= solenoid valve of the hot water
-
-
-
-
R
E
L
A
Y
- 9
-
-
-
-
-
-
-
-
-
- - -
O
F
F
-
-
-
-
-
-
By pressing OK, OFF becomes ON and the solenoid valve of hot water starts working. By pressing OK
again you go back to the OFF status
By pressing you go to TRIAC 1= static relay of command of the heating element of group 1
-
-
-
-
T
R
I
A
C
- 1
-
-
-
-
-
-
-
-
-
- - -
O
F
F
-
-
-
-
-
-
By pressing OK, OFF becomes ON and the heating element of group 1 starts working. By pressing OK
again you go back to the OFF status
By pressing you go to TRIAC 2, TRIAC 3 , TRIAC 4 (if they have been installed)
By pressing you go to RELAY STEAM = solenoid valve of the MCS – Milk Control System ( if it hsa
been installed)
-
-
R
E
L
A
Y
- S
T
E
A
M
-
-
-
-
-
- - -
- - O
F
F
- - - -
-
-
By pressing OK, OFF becomes ON and you you check the functioning of the steam solenoid valve. By
pressing OK again you go back to the OFF status
By pressing you check the state of the internal data memory and the control board EEPROM
-
-
-
-
-
E
E
P
R
O
M
-
-
-
-
-
-
-
-
-
-
- P
A
S
S
- -
-
-
-
-
If you see PASS on the screen, it means that the control board is OK
By pressing you check the connection between the control board and the panel of command
-
S
E
R
I
A
L
- L
I N
E
-
-
1
-
-
- - - -
- P
A
S
S
- - -
-
-
-
If you see PASS on the screen, it means that the connection is OK, if you see FAILURE it means that
there is not connection
By pressing you check the connection between the control board and the interface ( if it has been
installed) for the CASH SYSTEM,the GCS SYSTEM , the MCS SYSTEM
-
I
N
T
E
R
F
A
C
E
-
C
A
R
D
-
-
-
- - - - P
A
S
S
-
- - - - -
If you see PASS on the screen it means that the connection is OK
By pressing you check the proper functioning of the cash system
-
K
I
R
K
-
I N
T
E
R
F
A
C
E
-
-
- -
- - -
P
A
S
S
- - - - - -
If you see PASS on the screen it means that the connection is OK