INSTALLER’S INSTRUCTIONS
RELEASE 7.03
G
R
O
U
P
-
-
N
. 2
- S
E
T
-
-
- - - - - 9
5
, 0
°
C
. - - -
-
The default is 95 °Degrees C. Range is between 80° Degrees C to 110° Degrees C
Push or to change desired group temperature and press OK to confirm
You can set the 3rd and 4th group only if you have started them up in the SETTING MENU
Push or to change desired group temperature and press OK to confirm
After confirmation the display shows
-
-
D
E
L
T
A
-
T
O
T
A
L
-
-
-
-
-
- - -
4
, 0
°
C
. - -
-
-
-
This is the thermal Delta for the group heads.
The default is 4 ° Degrees C. Therefore, higher is the value, higher is the thermal stability of the groups.
Push or to change the groups thermal Delta and press OK to confirm
After confirmation the display shows
-
-
-
E
X
T
R
A
-
- S
E
T
-
-
-
-
-
-
- - 2
, 0
°
C
. - - -
-
-
This parameter increases the temperature of the group heads, if necessary, whenever they are inactive
for over 10 minutes (the manufacturer does not recommend a particular setting for this parameter, as it
varies depending on quality of coffee used and case-by-case scenarios)
The default is 2° Degrees C. Range is between 0° Degrees C to 6° Degrees C
Keep pressing the OK button until the display exits the TEMPERATURES menu and displays
- - T
E
M
P
E
R
A
T
U
R
E
S
- -
S
E
T
T
I N
G
S
- - - D
O
S
E
S
From the main menu, push or until SETTINGS blinks and press OK to access the settings submenu
-
G
R
O
U
P
-
N
.
-
x
-
O
N
-
-
-
- - - - - -
2
-
-
-
-
- - -
-
This parameter sets the electronic board to match the number of group heads mounted on the machine
(manufacturer sets up this parameter)
After confirmation the display shows
A
U
T
O
F
I L
L -
B
O
I
L
E
R
-
- - - - - 3
-
M
I
N
. -
-
- - -
This parameter sets the timeout of the boiler auto-filling mechanism and is usually modified depending on
the size of the boiler (recommended value: 4 minutes for 2-group machines, 6 minutes for 3 or 4-group
machines)The default is 3 minutes
After confirmation the display shows
-
-
-
O
N
-
-
C
O
F
F
E
E
-
-
-
-
-
-
- - 5
-
S
E
C
. - - -
-
-
This parameter activates the heating element in the group head each time the head is used to lay out
coffee, to avoid cooling down of the head after a few seconds (recommended value is 5 seconds)
The default is 5 seconds, the field range is between 0 seconds to 20 seconds.
Push or to change this parameter and press OK to confirm
After confirmation the display shows
-
-
-
D
O
S
E
S
-
P
R
O
G
-
-
-
-
-
-
Y
E
S
- - -
- - N
O
-
-
-
YES (the default) will blink
If YES is confirmed it is possible to proceed to programming of the doses of the group heads, while by
choosing NO this function is locked out.Push or to change this parameter and press OK to confirm
After confirmation the display shows
-
M
A
N
U
A
L
-
C
O
F
F
E
E
-
-
-
- - Y
E
S
-
-
- - - N
O
- -
-
YES (the default) will blink