9
Without the GCS system the display shows
C
O
F
F
E
E
-
G
R
O
U
P
-
N
.
1
s
1
- =
-
- 1
5
0
- -
- -
-
S1 (single short coffee ) blinks , push or to increase or decrease the value( default is 150)
Press OK to confirm
C
O
F
F
E
E
-
G
R
O
U
P
-
N
.
1
s
2
- =
-
- 3
0
0
- -
- -
-
S2 (double short coffee ) blinks, push or to increase or decrease the value(default is 300)
Press OK to confirm
C
O
F
F
E
E
-
G
R
O
U
P
-
N
.
1
s
3
- =
-
- 1
9
0
- -
- -
-
S3 (single long coffee ) blinks, push or to increase or decrease the value(default is 190)
Press OK to confirm
C
O
F
F
E
E
-
G
R
O
U
P
-
N
.
1
s
4
- =
-
- 3
6
0
- -
- -
-
S4 (double long coffee ) blinks, push or to increase or decrease the value(default is 360)
Press OK to confirm
C
O
F
F
E
E
-
G
R
O
U
P
-
N
.
2
s
1
- =
-
- 1
5
0
- -
- -
-
S1 (single short coffee ) blinks , push or to increase or decrease the value(default is 150)
Press OK to confirm. Repeat for each group until the display shows
- -
T
E
A
-
- -
G
R
O
U
P
-
-
-
S
1
=
- 3
.
0
-
- S
2
=
- 6
.
0
S1(single hot water dose)blinks, push or to increase or decrease the value( defualt is 3.0) Press OK
to confirm. S2 ( double hot water dose ) blinks , push or to increase or decrease the value( defualt is
6.0) Press OK to confirm.
Keep pressing the OK button until the display exits the DOSES menu and displays
- - T
E
M
P
E
R
A
T
U
R
E
S
- -
S
E
T
T
I N
G
S
- - - D
O
S
E
S
With the GCS system the display shows
- - G
R
. 1
-
-
-
S
e
l .
1
- -
Q
1
=
- 1
5
0
-
-
t 1
=
-
-
2
0
The display shows: Q1 dose from the selection 1 to the group 1 ( single short coffee ) using Grinder 1
You are not allowed to modify these parameters by using the serial palmer.
Press OK to confirm , the display shows
- - G
R
. 1
-
-
-
S
e
l .
1
- -
Q
1
=
- 1
5
0
-
-
t 2
=
-
-
2
0
The display shows : Q1 dose from selection 1 to the group 1 (single short coffee)using the Grinder 2
Press OK to confirm , the display shows
- - G
R
. 1
-
-
-
S
e
l .
2
- -
Q
1
=
- 3
0
0
-
-
t 2
=
-
-
2
0
The display shows : Q1 dose from selection 2 to the group 1 (double short coffee)using the Grinder 1
Press OK to confirm , the display shows
- - G
R
. 1
-
-
-
S
e
l .
2
- -
Q
2
=
- 3
0
0
-
-
t 2
=
-
-
2
0
The display shows : Q2 dose from selection 2 to the group 1 (double short coffee)using the Grinder 2
Going on this way you will visualize all doses parameters referred to the installed groups until the display
wil show TEA GROUP as already shown in the “WITHOUT GCS SUBMENU”
Sel 1 = single short coffee
Sel 2 = double short coffee