Dametric AB BRM-DM1/2 User manual
BRM-DM12 UM EN.docx Feb. 18, 2020 Page 6 of 10
5 Parameter description
5.1 GMS/BRM-DM1/2
BRM GMS System GMS measure system: 1:GMS-V1T01, 2:GMS-V1A01, 3:GMS-V1A02, 4:GMS-
V2A01, 5:GMS-V2T01, 6:GMS-V1X01, 7:GMS-V1X02.
BRM Can Node no. Node number, normal 1, use 2 for flats side in a CD-refiner. (GMS-V2A01 and
GMS-V2T01).
BRM Ind.bus type 0=no bus, 1= Profinet, 2=Profibus, 3=Ethernet IP.
BRM Serial no. The unit serial number.
BRM HW. Rev.no. Actual hardware revision.
BRM DCS clock Synch value from DCS/PLC over the industrial bus. 0 means no contact, 1-255 is a
value that increases continuously.
BRM Test func. Test function (not used).
BRM Date Date and time.
5.2 CAN-Eth.-Conv.
The function is only valid and shown in a BRM-DM2.
CEC Off/ON/On-Al Off=disconnected, On=connected, On+Alarm=connected to the sum alarm function.
CEC IP Address IP-address
CEC IP Mask IP-mask.
5.3 Rotor position
POM Off/On/On+Al Off=disconnected, On=connected, On+Alarm=connected to the sum alarm function.
POM Direction Direction, set to 0 or 1 depending of the type and thread of the control rod.
POM Ratio Ratio, set 1.00 for a flat refiner and like 0.20 for a conical.
POM Al.Lim. 1HH Alarm limit 1, high-high.
POM Al.Lim. 2H Alarm limit 2, high.
POM Al.Lim. 3L Alarm limit 1, low.
POM Zero calibr. Zero calibration, see the calibration manual for actual measure system.
POM Span calibr. Span calibration, see the calibration manual for actual measure system.
POM Work mode Shows alternately distance, and speed for the latest rotor travel.
5.4 Ref. vibration
VIM Off/On/On+Al Off=disconnected, On=connected, On+Alarm=connected to the sum alarm function.
VIM Al.Lim. 1HH Alarm limit 1, high-high.
VIM Al.Lim. 2H Alarm limit 2, high.
5.5 Touch vibration
TVD Off/On/On+Al Off=disconnected, On=connected, On+Alarm=connected to the sum alarm function.
TVD Sens. Idle Sensitivity at idle.
TVD Sens. Prod. Sensitivity at production.
TVD Al.lim.1 Hg2 Alarm limit 1, idle, high-high.
TVD Al.lim.2 Hg1 Alarm limit 2, idle, high.
TVD Al.lim.3 Lg2 Alarm limit 3, production, high-high.
TVD Al.lim.4 Lg1 Alarm limit 4, production, high.
TVD Pro.adj.sen. Adjusted sensitivity at production. The value can also be controlled from an external
source, like an industrial bus.