Introduction
Superheat controller EKE 1B is for use where superheat must be accurately controlled,
typically in commercial air conditioning, heat pumps, commercial refrigeration, food retailing
and industrial applications.
Compatible valves: Danfoss ETS 6 / ETS / ETS Colibri®, KVS / KVS Colibri® and CCM / CCMT /
CTR valves.
Reference: For details please see EKE data sheet.
1. Superheat controller: standalone / network
2. Valve driver
ETS Colibri®
Applications
Dimensions in mm
EKE 1B
More info
Communication
Weight: 152 gram
Reference signal
Installation guide
Electronic superheat controller
Type EKE 1B
Question and Answer IconNeed help?

Do you have a question about the Danfoss EKE 1B and is the answer not in the manual?

Danfoss EKE 1B Specifications

General IconGeneral
BrandDanfoss
ModelEKE 1B
CategoryController
LanguageEnglish

Summary

Introduction to EKE 1 B Superheat Controller

Applications of EKE 1 B Controller

Superheat Controller: Standalone Network

Describes standalone and networked use of the superheat controller. Typically for commercial AC, heat pumps, refrigeration.

EKE 1 B as a Valve Driver

Illustrates the EKE 1B as a valve driver, showing connection to ETS Colibri and reference signal.

Dimensions of EKE 1 B

Technical Specifications of EKE 1 B

EKE 1 B Power Supply Details

Details power supply requirements, isolation, AC/DC input, and consumption for the EKE 1B controller.

EKE 1 B InputOutput (IO) Specifications

Lists and specifies Analog Inputs, Auxiliary Supplies, Digital Inputs, Digital Output, Stepper motor, Battery backup, and Communication interfaces.

General Features and Warnings for EKE 1 B

EKE 1 B Plastic Housing Features

Describes housing features like DIN rail mounting, self-extinguishing properties, and ball test compliance.

EKE 1 B Other Product Features

Lists operating conditions, storage conditions, IP rating, pollution environment suitability, and immunity categories.

EKE 1 B CE Compliance Standards

Outlines EU standards compliance for Low Voltage and Electromagnetic Compatibility (EMC).

General Safety Warnings for EKE 1 B

Provides general warnings regarding incorrect use, qualified personnel, safety devices, and user liability.

EKE 1 B Installation Warnings

Covers recommended mounting, compliance with standards, electrical safety precautions, and environmental exposure limits.

EKE 1 B Product Specific Warnings

Specific warnings about using Class II transformers, connecting mains voltage to inputs, battery backup function, and external power supplies.

EKE 1 B Mounting and Connection Overview

DIN Rail Mounting and Demounting

Explains the procedure for mounting and demounting the EKE 1B unit onto a 35 mm DIN rail.

EKE 1 B Terminal Connection Overview

Visual representation of the EKE 1B's terminal layout, showing RS485, ANALOG/DIGITAL INPUT, and CAN - RJ connections.

EKE 1 B Connection Overview and Related Components

Power Supply and Valve Connections

Shows power supply, ETS6 valve, and ON/OFF solenoid valve connections to EKE 1B.

MMIGRS2 Display and MMIMYK Gateway Connections

Illustrates connections for MMIGRS2 Display and MMIMYK Gateway to the EKE 1B via CANbus.

Temperature Sensor Mounting and Pressure Transmitter Installation

Temperature Sensor Mounting Guide

Provides step-by-step instructions and important notes for mounting temperature sensors on an evaporator.

Pressure Transmitter Installation Guidance

Offers guidance on installing pressure transmitters, emphasizing proximity to the temperature sensor and load percentage.

EKE Controller Power Supply Guidelines

Discusses power supply sharing capabilities and good practices for connecting power to EKE controllers.

EKE 1 B Relay Outputs, Cable Lengths, and Modbus Connection

EKE 1 B Relay Output Functionality

Explains the function and limitations of the EKE 1B's single SPDT relay output for solenoid valves or alarms.

EKE 1 B Cable Length and Wire Size Specifications

Lists maximum cable lengths and wire sizes for various EKE 1B connections like analog inputs, sensors, power, and communication.

EKE 1 B Cable and Wiring Best Practices

Provides guidelines on cable distance, wire separation from mains wiring, and impact on measurement accuracy.

EKE 1 B Modbus Communication Setup

Details recommended Modbus cable specifications, RS485 interface, device limits, termination, baud rates, and default address.

EKE 1 B Stepper Motor and Valve Connections

EKE 1 B Stepper Motor Output Operation

Describes how stepper motors are driven in bipolar mode and connected via M12 connectors, including configuration notes.

Valve Cable Connections for EKE 1 B

Shows pin assignments for Danfoss M12 cables connecting to ETS, KVS, CCM, and CCMT valves.

ETS 6 Stepper Motor Valve Wiring

Details wire color assignments for ETS 6 stepper motor valves and their connection to EKE terminals.

Guideline for Long M12 Cables with Stepper Motor Valves

Offers advice on overcoming performance degradation with long M12 cables by adjusting valve driver settings.

Parameter Settings for Long M12 Cables

Provides specific parameter settings (e.g., valve drive current) for different cable lengths and valve models.

EKE 1 B User Interface and Configuration Tools

EKE 1 B LED Status Indicators

Explains the meaning of the status and valve operation LEDs on the EKE 1B controller.

EKE 1 B User Interface Options

Lists the available user interfaces for setting up the EKE 1B: KoolProg software, MMIGRS2 display, and Modbus.

EKE 1 B Configuration with KoolProg Software

Introduces KoolProg as a free software tool for configuring EKE controllers, monitoring status, and analyzing behavior.

Reliable USB Connection Tips for KoolProg

Provides crucial tips for ensuring a reliable USB connection between a host device, MMIMYK Gateway, and KoolProg software.

MMIGRS2 Display for EKE 1 B Setup and Operation

MMIGRS2 Display Connection Notes

Specifies maximum cable distance for MMIGRS2 display connection and CANbus termination requirements.

MMIGRS2 Display Back View Details

Shows the back view of the MMIGRS2 display, highlighting connection types for different cable lengths.

MMIGRS2 Display Front View and Homescreen

Illustrates the front view of the MMIGRS2 display, detailing navigation buttons and the homescreen display format.

EKE 1 B Setup Wizard Configuration

Using the Setup Wizard via MMIGRS2 Display

Guides users through the setup wizard process using the MMIGRS2 display for initial controller configuration.

Setup Wizard Usage Notes and Limitations

Offers advice on using the wizard with insufficient data, limitations of the wizard, and availability in KoolProg.

Quick Guide for EKE 1 B Parameter Selection

Parameter Selection as Valve Driver

Section focusing on parameter selection when the EKE 1B is used as a valve driver.

Parameter Selection as Superheat Controller

Section focusing on parameter selection when the EKE 1B is used as a superheat controller.

EKE 1 B Common Parameter Identification

EKE 1 B Parameter List and Descriptions

Details specific parameters like Main switch, Operation mode, Driver reference, Valve configuration, Refrigerant, sensor configurations, and superheat settings.

Related Products for EKE 1 B System

MMIGRS2 Display and MMIMYK Gateway

User interface module and gateway for EKE controllers.

Compatible Transducers and Sensors

Compatible pressure transducers and temperature sensors for EKE applications.

Cables and Stepper Motor Valves

ACCBI cables, M12 cables, and compatible stepper motor valves for EKE controller.

Related product manuals