IK3 maintenance tips
This product is designed for use in an industrial environment that may shorten the product's lifespan. Use
these tips to maximize the lifespan of the product.
Use the hook/belt provided with the transmitter to prevent the transmitter from falling
Do not clean the transmitter with solvents or pressurized water; use a damp cloth or soft brush for
cleaning
If the push buttons show signs of deterioration, contact the Authorized Technical Service for repair
Check if the battery contacts are correct, otherwise replace them.
Ensure that the product is supplied with AAA alkaline batteries or has a rechargeable battery
Be sure to recharge or replace battery regularly
Maintenance tips quick reference
Troubleshooting (400-900 MHz)
The transmitter has status monitoring LED's which help identify irregularities. The most common signals
are contained in the table below:
Color and frequency Pulse frequency Description Action
Green | continuous Working Operate
Green | slow pulses Latency; no action has been taken for some time Press START to return to operation
mode
Red | slow pulses Low battery signal Replace or recharge battery
Red | fast pulses EEPROM module missing or corrupt Check EEPROM and reprogram if
necessary
Red | double pulses A maneuver is activated at transmitter start up process;
may indicate hardware damage if no order is active
Release maneuver or replace
transmitter if necessary
Red | continuous General hardware failure Replace transmitter
Troubleshooting 2.4 GHz
The transmitter has status monitoring LED's which help identify irregularities. The most common signals
are in the table below:
LED color | Frequency Pulse Frequency Description Action
Blue / fast pulses
Starting the system,establishing
communication with radio and EEPROM.
Wait
Blue | continuous
Stand-by. Set up system, waiting user’s action. Press START to enter Operation mode.