EasyManua.ls Logo

Danfoss Old ICAD 900 series User Manual

Danfoss Old ICAD 900 series
18 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Quick Start Guide
ICM/ICAD Motorized Valves
Installation, Programming, and Troubleshooting
© Danfoss | DCS (MWA) | 2016.07
DKRCI.EI.HT0.B3.22 | 520H4763 | 1
The ICM motorized valve is comprised of up to 4
components:
the valve body – often referred to as the ICV body
because it is used for ICM motor valves, ICS pilot
operated valves and ICLX solenoid valves.
the function module – the ow regulating part of
the valve
the top cover – on the ICM 20 through 65, the
function module and top cover are one part
the ICAD motor actuator – the “brains” of the
valve
Actuator ICAD 600A ICAD 1200A Old ICAD 600* Old ICAD 900* Old ICAD 1200*
Valve Size ICM 20 ICM 40 ICM 20 ICM 40 ICM 40
Valve Size ICM 25 ICM 50 ICM 25 ICM 50 ICM 50
Valve Size ICM 32 ICM 65 ICM 32 ICM 65 ICM 65
Valve Size ICM 100 ICM 100
Valve Size ICM 125 ICM 125
Valve Size ICM 150 ICM 150
ICM/ICAD overview The combinations of valve and actuator are as follows:
* ICAD 600, 900 and 1200 were discontinued at the end of 2014. ICAD 600A is a direct replacement of ICAD 600 and ICAD 1200A is a
direct replacement of ICAD 900 or ICAD 1200.
Question and Answer IconNeed help?

Do you have a question about the Danfoss Old ICAD 900 series and is the answer not in the manual?

Danfoss Old ICAD 900 series Specifications

General IconGeneral
BrandDanfoss
ModelOld ICAD 900 series
CategoryControl Unit
LanguageEnglish

Summary

ICM/ICAD Overview

Valve Installation Procedures

Valve Installation Details

ICAD Motor Mounting and Calibration

Steps for mounting the ICAD motor and initial calibration procedures.

Electrical Data and Wiring

ICAD Communication and Power Wiring

Describes the pinouts and wire colors for ICAD communication and power cables.

ICAD Wiring Diagrams

ICAD to PLC/Third-Party Wiring

Illustrates wiring diagrams for connecting ICAD to PLCs or other external systems.

ICAD to Danfoss EKC Controller Wiring

Shows wiring diagrams for connecting ICAD to Danfoss EKC controllers.

ICAD Wiring to EKE Controller

EKE Controller Wiring Connections

Provides specific wiring diagrams for connecting ICAD to Danfoss EKE controllers.

Operating the ICAD Menu

Navigating ICAD Parameters

Steps to access and navigate parameters within the ICAD menu.

ICAD Programming Parameters

Parameters: OD, Mode, AI Signal

Details parameters like Opening Degree, Operation Mode, and Analog Input signal types.

ICAD Programming Details

Parameters: Speed, Encoder, Configuration

Covers parameters for closing speed, encoder operation, forced closing, and ICM configuration.

Troubleshooting Overview

Common ICAD Alarms List

Details common alarms such as No Valve type selected, Controller fault, and Analog input error.

Troubleshooting Specific Issues

Troubleshooting Alarms A1, A3, A9

Explains alarms A1 (no valve type), A3 (signal out of range), and A9 (valve locked).