Service guide | Disassembling and assembling PAH 50-100
8
180R9098 | 521B1072 | DKCFN.PI.011.NC5.02 | 06.2017
2. Check the bearing (the black part) for
large wear grooves (not critical).
2. Check that the bushings are free from
seizure and large scratches.
3. Ensure that the pistons can move freely in
the bushings.
1. Check the outer bearing surface for large
wear grooves (not critical).
2.3. Cylinder barrel
2.4. Housing
1. Check that the surface of the swash plate
is smooth and without any large scratches
(depth more than 0.1 mm).
2.5. Swash plate