6
DIL switch settings
Heating selection
Slide the DIL switches to the settings
required (see below)
Cooling selection
COOL
ON/OFF
6 CYCLES
°F
COOL
NO DELAY
4 MIN DELAY
°F
HEAT
CHRONO
3 CYCLES
°C
HEAT
2 MIN DELAY
°C
ON/OFF - boiler switches ON
when below set temperature
and OFF when above
CHRONO -
energy saving
feature which  res the boiler
at regular intervals to maintain
a set temperature, achieving a
constant ambient environment
for the user.
use 6 Cycles for radiator
systems
use 3 Cycles for
under oor heating
COMPRESSOR
DELAY