pressure
(see Series20 Axial Piston
Pumps, Service Manual
and Repair Instruction)
OK
Inspect
charge pump
(see Series20 Axial Piston
Pumps, Service Manual
and Repair Instruction)
Inspect
inlet filter
Repair or replace
(see Series20 Axial Piston
Pumps, Service Manual
and Repair Instruction)
Defective
Replace
Defective
Inspect charge
pressure relief valve
(see Series20 Axial Piston
Pumps, Service Manual
and Repair Instruction)
Repair or replace
(see Series20 Axial Piston
Pumps, Service Manual
and Repair Instruction)
Clogged
Inspect purge
relief valve
at motor
(see page 21)
Repair or
replace the
valve block
(see page 19)
Defective
Replace
transmission
(pump + motor)
Inspect
control valve
(see Series20 Axial Piston
Pumps, Service Manual
and Repair Instruction)
Replace
control valve
(see Series20 Axial Piston
Pumps, Service Manual
and Repair Instruction)
Defective
Inspect motor
by-pass valve
(if used)
Repair
or replace
Defective
Check system
pressure
(see page 13)
to low in
neutral and
forward or
reverse
to low in
forward or
reverse
to low in
neutral
OK
OKOK OK
OK OK OK