DANFOSS RANDALL
SET2E
with terminals L - 2 and 1 - 5 linked
MAINS WATER HEATING
NOTE
This conversion
applies only if..
An additional terminal
block is required
where these discon-
nected leads (or pairs
of leads) should be
terminated
N L ON COM OFF ON COM OFF
NL 1 23 4 56 ABCD
DANFOSS RANDALL SET 2
NL 1 23 4 56
Direct plug-in
replacement
DANFOSS RANDALL TSR2P
3 1,2 5,6 - - 7 - -
Terminals 1 & 2
are linked and
5 & 6 are linked
4
DANFOSS RANDALL 3060 & 3020P 1,7 6 4 - - 2 - - 3 5
DANFOSS RANDALL 102/102E 5 3,6 1 - - 2 - -
DANFOSS RANDALL 701 N L 3 6 4 1 5 2
HONEYWELL ST6200 N L 3 - 1 4 - 2
HORSTMANN CORAL 423 & 424 2,3 1 Boiler (8) - - AirStat (8) - - 4,7 5 6
HORSTMANN DIADEM 425
NL 1 23 4 56
Programme
selectors linked
HORSTMANN DIADEM 525
NL 1 23 4 56
Programme
selectors linked
HORSTMANN DIAMOND 423 N L,1,3 2 - - 4 - - 5 6
HORSTMANN DIAMOND 424 N L,1,3 2 - - 4 - - 5
LANDIS & GYR RWB2
NL 3 -1 4 -2
Programme
selectors linked
POTTERTON 423 N L,1,3 2 - - 4 - - 5 6
POTTERTON MINI-MINDER
NL 3 -1 4 -2
Programme
selectors linked