EasyManua.ls Logo

Danfoss TP4000 User Manual

Danfoss TP4000
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Fig.1
TP4000
User Instructions
Fig.2
Before programming the thermostat press and release the RESET button to restart
the unit. (Fig. 1)
Setting the Clock and Day
The time is set in the factory and therefore it will not normally be necessary to do this
on site.
Accepting the Factory Pre-settings
The TP4000 has pre-set times already programmed in, which often suit most people
(see table below).
To adjust the factory pre-settings & set your own time and temperature
programmes
a) Press PROG (Fig. 2) Until 1st pre-set time and temperature appears in display (Fig.
3).
b) Use + or – buttons (Fig. 4) to adjust the TIME (press and hold to change in 10 min
increments).
c) Use Λ or V buttons (Fig. 5) to adjust the TEMPERATURE.
d) Press PROG (Fig. 2) to move to next preset time & temp (Event 2) (Fig. 6).
e) Repeat steps b, c & d for programming Events 3, 4, 5 & 6.
Returning to RUN mode
Press PROG (Fig. 2) – the colon in the LCD display will start to ash (Fig. 7).
Temporary User Overrides
Fig.5
Fig.4
Fig.6
Fig.7
Event Time Temp. °C
1 06:30 20
2 08:30 15
3 11:30 20
4 13:30 15
5 16:30 21
6 22:30 15
RESET
Fig.3
Fig.9
Fig.10
Selection of time
or actual room
temperature in main
LCD display
Temporary
override of
programmed
temperature
press
together
Frost
Protection
Fig.8
The TP4000 has several useful overrides which can be selected without aecting the
thermostat programming.
Selection of time or actual room temperature in main LCD displaypress +
and – together to change between settings (Fig. 8).
Temporary override of programmed temperature – press Λ or V until required
temperature is displayed (override will automatically cancel at beginning of next
programmed event) (Fig. 9).
Frost Protection – a constant low temperature can be selected whilst away from
home - press Λ and V together (Fig.10). Then use Λ or V to select the required
temperature. To return to automatic programming press Λ and V together
again.
The TP4000 is both a programmer and a room thermostat. It allows you to programme
up to 6 times and temperatures at which your heating will come on and go o each
day.

Other manuals for Danfoss TP4000

Question and Answer IconNeed help?

Do you have a question about the Danfoss TP4000 and is the answer not in the manual?

Danfoss TP4000 Specifications

General IconGeneral
DisplayLCD
Temperature Range5°C to 30°C
Power Supply2 x AA batteries
Control ModeOn/Off
MountingWall-mounted
Protection ClassIP30
TypeRoom Thermostat
Accuracy±0.5°C

Summary

Setting the Clock and Day

Accepting Factory Pre-settings

Factory Pre-set Times

Table showing pre-set times and temperatures for heating events.

Programming Time and Temperature

Select Event and Time

Press PROG to cycle through pre-set times and temperatures.

Adjusting Time

Use + or - buttons to adjust the programmed time in 10-minute increments.

Adjusting Temperature

Use A or V buttons to adjust the desired temperature for the event.

Advance to Next Event

Press PROG to move to the next event and repeat programming.

Returning to RUN Mode

Activate RUN Mode

Press PROG until the colon in the LCD display starts to flash.

Temporary User Overrides

Displaying Time or Room Temperature

Press + and - together to switch between displaying time and room temperature.

Temporary Temperature Override

Press Ʌ or V to set a temporary temperature, cancelling at the next programmed event.

Frost Protection Mode

Press A and V together to set frost protection, then use A or V to select temperature.

Battery Replacement

Low Battery Warning and Replacement

Low battery symbol indicates replacement needed within 15 days; RESET required after replacement.