EasyManua.ls Logo

Danfoss VLT 5062 - Main Supply 3 X 400-500 V

Danfoss VLT 5062
123 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VL 5000 Crane
Technical
Data
Mains supply 3 x 400-500 V
According to international
requirements VLT type 5072 5102 5152 5202
Output
current
I
VLT,N
[A] (S3 60%) (400-500 V) 100 139 201 246
I
VLT, MAX
(60 s) [A] (400-500 V) 159 221 301 369
Output
S
VLT,N
(S3 60%) [kVA]
(400-500 V) 67.5 93.9 135.8 166.2
Typical shaft output P
VLT,N
[kW] 45 65 90 110
Typical shaft output P
VLT,N
[HP] 61 89 125 150
Max. cable cross-section to motor
(400-500 V) [mm
2
]
3)
95 120 2x70 2x185
Max. cable cross-section to brake
(400-500 V) [mm
2
]
4)
95 120 2x35 2x70
Max. cable cross-section to motor
(400-500 V) AWG]
2) 3)
3/0 4/0 2x2/0
2x350
MCM
Max. cable cross-section to brake
(400-500 V) AWG]
2) 4)
3/0 4/0 2x3 2x2/0
Max input current I
L,MAX
(S3 60%) [A] (400 V) 89 124 186 224
Max. cable cross-section to power
(400-500 V) [mm
2
]
3)
95 120 2x70 2x185
Max. cable cross-section to power
(400-500V) [AWG]
2) 3)
3/0 4/0 2x2/0
2x350
MCM
Efficiency
0.96-
0.97
0.96-
0.97
0.97-
0.98
0.97-
0.98
Weight IP 20 EB/IP 00 [kg] 109 109 89 134
Power loss at max. load [W] 1860 2250 2828 3231
Enclosure IP20 IP20 IP00 IP00
1. For type of fuse see section Fuses.
2. American wire gauge.
3. Connection Dual M10 screws.
4. Connection Dual M8 screws.
MG.50.N4.02 - VLT is a registered Danfoss trademark
21

Other manuals for Danfoss VLT 5062

Related product manuals