EasyManua.ls Logo

Dantherm CDP 70 User Manual

Dantherm CDP 70
6 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1
052719 • Version 1.0 • 13.08.2019
1.
Remove the front of the unit.
Remove the PPI lter and replace with new as
per partslist.
The new PPI lter must be right up against both
ends of the cabinet.
Make sure that the hole is furthest away from the
front as shown.
2.
Release humidity sensor from drip tray
and retract it back in to the compressor
compartment.
In the compressor compartment pull the sensor
through the rear hole in the bottom plate.
3.
Find the compressor compartment cover with
the pre-mounted bracket for the humidity
sensor.
Dismount the old cover.
Mount the new cover and move the sensor to
the front.
Note: The bracket is
mounted o center
to t the hole in the
PPI lter
Note: For CDP/CDF 40 and 50 the lters
must be cut according to this illustra-
tion.
1237mm
0mm
130mm
200mm
1447mm
Replacing RH/T sensor (en)
Applies for the following products with serial no. lower than:
CDP/CDF 40: 1809131526904
CDP/CDF 50: 1809241528179
CDP/CDF 70: 1810031531072

Other manuals for Dantherm CDP 70

Questions and Answers:

Dantherm CDP 70 Specifications

General IconGeneral
ModelCDP 70
Dehumidification Capacity70 liters/day
RefrigerantR410A
Weight54 kg
Power Supply230 V / 50 Hz
Sound level52 dB(A)
Operating temperature range3-35 °C

Summary

Replacing RH/T Sensor

Remove Front Panel and Replace Filter

Remove the unit's front, then replace the PPI filter as per partslist, ensuring correct alignment.

Release and Retract Humidity Sensor

Release the humidity sensor from the drip tray and pull it through the rear hole in the bottom plate.

Mount New Compressor Compartment Cover

Find the cover with the pre-mounted bracket, dismount the old cover, and mount the new one.

Mount Humidity Sensor and Cable Binders

Mount the humidity sensor onto the bracket using PPI filter and two cable binders.

Remount Front Panel

Reattach the front panel, ensuring the sensor is visible through the grille.

Download Latest Software Version

Insert USB dongle to auto-detect and install the new software version; a log file is stored.

Related product manuals