Remove the unit's front, then replace the PPI filter as per partslist, ensuring correct alignment.
Release the humidity sensor from the drip tray and pull it through the rear hole in the bottom plate.
Find the cover with the pre-mounted bracket, dismount the old cover, and mount the new one.
Mount the humidity sensor onto the bracket using PPI filter and two cable binders.
Reattach the front panel, ensuring the sensor is visible through the grille.
Insert USB dongle to auto-detect and install the new software version; a log file is stored.