I-Class
Media Settings (continued)
Menu Item Details
SENSOR TYPE
Selects the Top Of Form (TOF) sensing method used to
determine the leading edge of the label, where:
GAP
Senses the gaps or notches in the media.
CONTINUOUS TOF sensing is not used; see LABEL LENGTH.
REFLECTIVE
Senses the reflective (black) marks on the underside of
the media.
LABEL LENGTH
Determines the length of the label when the SENSOR
TYPE is set
to CONTINUOUS, where:
04.00in (0-99.99)
Is the desired length of the format.
MAXIMUM LABEL LENGTH
Sets the distance that the printer will feed GAP or
REFLECTIVE media before declaring a TOF fault, where:
16.00in (0-99.99)
Is the length of travel to detect a TOF gap or mark.
Note: This distance should be 2.5 to 3 times the
length of the label.
PAPER OUT DISTANCE Sets the Out Of Stock fault (empty) distance, where:
00.25in (0-99.99) Is the attempted length of feed before empty is
declared.
Note: If using clear or translucent media, this
setting should be longer than the length of
the label.
LABEL WIDTH
Sets the maximum printable width. Objects extending
beyond this limit will NOT print, where:
XX (X-XX) Is the maximum width; see Appendix A for the model
dependant default and range.
RIBBON LOW OPTIONS
Defines the response when THERMAL TRANSFER is
selected and the ribbon supply diminishes, where:
RIBBON LOW DIAMETER
Sets the threshold that will trigger a Low Ribbon
Warning prompt, where:
1.40in (1.00 – 2.00)
Is the outer diameter size of the ribbon roll.