EasyManuals Logo

Dataprobe iBoot G2+ Manual&Nbsp;

Dataprobe iBoot G2+
35 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #30 background imageLoading...
Page #30 background image
V130108E iBoot-G2+ Page 30
Event Commands
These commands are only available to the
administrator.
get events
This command displays all scheduled events as shown
below. Example:
DateTimeRepeatActionOutlet
1.12/17/201216:30every0Day(s)OffMainRun
2.12/18/201204:00every1Day(s)CycleExp1Run
3.12/17/201214:45every0Day(s)OnMainHold
4.every0Day(s)OnMainRun
5.every0Day(s)OnMainRun
6.every0Day(s)
OnMainRun
7.every0Day(s)OnMainRun
8.every0Day(s)OnMainRun
set time server <dotted decimal> This command is used to set the IP Address of a
network time server.
69.90.182.55
set timezone <-12 – 12> This command sets the time zone offset for the iBoot
location.
-5
set time enable <yes | no> This command enables or disables the use of the time
server and scheduled events.
Note: When Adding new events through the CLI. Set
this to no to prevent unintended power switching
No
get time Displays the current time and time server (when
enabled)
CurrentTime:16:10:4101/27/2010
Server:64.90.182.55
TimeZone:‐4
set event <1-8> <run | hold> This command is used to all the event to run, or put the
event on hold
run
set event <1-8> date <mm/dd/yyyy>
This command is used to set the scheduled action’s
start date.
set event <1-8> time <hh:mm> This command is used to set the time the scheduled
action will occur in 24 hour format.
set event <1-8> repeat < minute | hour |
day>
This command is used to set the increments for
repeating scheduled actions
set event <1-8> mult <0-999> This command sets how often the event will repeat, the
number of increments (as set by the command above)
before the next event.
set event <1-8> action <on | off | cycle > This command is used to set the scheduled action.
del event <1-8> This command deletes the scheduled action.

Other manuals for Dataprobe iBoot G2+

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dataprobe iBoot G2+ and is the answer not in the manual?

Dataprobe iBoot G2+ Specifications

General IconGeneral
BrandDataprobe
ModeliBoot G2+
CategorySwitch
LanguageEnglish

Related product manuals