V130108E iBoot-G2+ Page 33
11. Troubleshooting
The iBoot-G2+ has a recessed pushbutton switch in the event
the unit is not performing as expected. Use the pushbutton as
follows:
Action Result
Momentary Soft Reset. Will not change outlet
status.
5 Seconds push Reset to Factory Defaults. Hold the
button in until the Outlet LED is blinking,
then release.
Hold in while and
Power up the
iBoot
Recovery Mode. Allows upload of new
firmware to the current IP Address. Will
recover to the Factory default IP
Address 192.168.1.254 if the database
has been corrupted.