FP-550F 41
Result: One byte, containing the letter = P - no error; = F - error.
The fiscal memory has a fixed capacity for a set number of entries and for this reason
the command can be performed not more than 16 times.
61h (97) READING THE SET TAX RATES
Data field: None
Response: TaxA,TaxB,TaxC,TaxD
Tax A set tax rate
Tax B set tax rate
Tax C set tax rate
Tax D set tax rate
62h (98) SETTING THE TAX REGISTRATION NUMBER
Data field: None
Response: Text
text: The tax registration number as a text
64h (100) SHOWING TEXT ON DISPLAY
Data field: Text
Response: None
Text A text of no more than 40 symbols sent for displaying. If ASCII sym-
bols must be sent and they are smaller than 20h (control strings) they are increased to
40h and are preceded by 10h.
Example: To send 1Bh, 4Bh, 00h the data field will have to contain 10h, 5 Bh, 10h,
40h.
65h (101) SETTING THE OPERATOR’S PASSWORD.
Data field: <OpCode> <PldPwd> <NeewPwd>
Response: None
OpCode Operator’s code
OldPwd Old password (4 to 6 digits)
NewPwd New password (4 to 6 digits)
Sets one of the eight operator’s passwords, which will be demanded upon opening a
fiscal receipt. After three erroneous password entries the printer will block, it must
then be switched OFF and ON again to continue operating.
After intialization or closure of the operational memory all eight passwords are
“0000”.
66h (102) ENTERING OPERATOR’S NAME
Data field: <OpCode> <Pwd> <OpName>
Response: None
OpCode Operator’s code
Pwd Password (4 to 6 digits)