3
Power Connection (Single Phase Models)
IMPORTANT INFORMATION: Your Davey pump is Double Insulated
to Water Circuit. If equipotential bonding structure is required, then
a Equipotential Bonding Point is provided. (Please refer to your local
statutes and regulations for AS/NZ 3000 Wiring standards).
Davey Silensors are suitable for connection to a nominal 240 volt 50Hz power supply and are
equipped with a ex lead and 3 pin plug. If a power outlet is not available within 3 metres of
the pump, a 3 pin power point in a safe, dry place, may need to be provided by an electrician.
Extension cords are unsafe around pools - and should be avoided. If the supply cord of this
product is damaged it must be replaced by the Dealer or manufacturer.
Davey Water Products recommends that all installations are tted with
earth leakage or residual current protection devices.
CAUTION:
In the interest of safety, we advise that all brands and types of pool pumps
must be installed in accordance with AS3000 wiring rules or equivalent
In accordance with AS/NZS 60335.2.41 we are obliged to inform you that
this pump is not to be used by children or inrm persons and must not be
used as a toy by children.
If the pump and lter are located below pool water level, it is necessary
to t isolating valves in the pipe between the pump and the skimmer box
and in the return pipe from the lter to the pool.
The ttings on this product are constructed of ABS. Some PVC jointing
compounds are incompatible with ABS. Check compound suitability
before use.
Warning! Ensure that an electrical isolation switch is located with easy
access so that the pump can be switched off in an emergency.
An isolating transformer or a residual current device (RCD) having a
rated residual operating current not exceeding 30mA shall be supplied.