FAN ONLY OPERATION
The Davies, Craig LCD EWP/Fan Digital Controller is programmed to earth the electric
fan relay at 3°C above the set point. The Controller will continue to operate the fan until
the coolant temperature is below the set point.
To enable fan only control without using an Electric Water Pump, connect the remote
LED (supplied) to the controller wires labelled “PUMP” as shown below
Please refer to the Figure 6 (page 9) for fan to controller wiring details. Please call
Davies, Craig at (03)93691234 if you require another remote LED to complete the
wiring.
EWP & FAN DIGITAL CONTROLLER TECHNICAL
SPECIFICATIONS
Input Voltage
12VDC to 29VDC
Output Voltage
6V to 29V
Max. Current
12A
Operating
Temperature
-20ºC to 120ºC (-4ºF to 248ºF)
Setting
Temperatures
C
4
To
11
F
10
To
230º
Fan Cut in
Temperature
+3ºC/5.4°F above the set temperature
Sensor Type
Thermistor
Time Out
3 Min. (or Set 10ºC/14°F) after ignition OFF
Weight
100 grams (3.5 oz.)
Dimensions
110mm (L) X 90mm (W) X 30mm (D)
[41/3” (L) x 31/2” (W) x 1.1” (D)]
A 12V LED connected to the Pump
connector
Figure 5: Fan Only Connection Wiring Diagram