EasyManua.ls Logo

DAVIS Vantage Pro - Testing Commands

DAVIS Vantage Pro
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 9 of 52
Beware that some systems may translate a new line character into both a new line and a carriage
return which will cause intermittent operation when using a Vantage Pro2 console.
In the following command examples, lines starting with “>” are set to the console, and lines
starting with “<” are received from the console.
Character symbols
Symbol Value Name
<CR>
0x0D Carriage return, “\r”
<LF>
0x0A Line Feed, “\n”
<ACK>
0x06 Acknowledge
<NAK>
0x21 Not Acknowledge
<CANCEL>
0x18 Bad CRC code
<0xdd>
0xdd Character code specified in hex.
1. Testing commands
"TEST"
It sends the string “TEST\n” back. Mostly useful when using HyperTerminal for testing a
connection to the console.
Example:
>"TEST"<LF>
<"TEST"<LF><CR>
"WRD"<0x12><0x4d>
It is the same command sequence used by earlier Davis weather stations to read the Station
Type value. The station will respond with an <ACK> and then a one byte identifier, which
can be one of these values:
Value Station Value Station
0 Wizard III 4 GroWeather
1 Wizard II 5 Energy Enviromontor
2 Monitor 6 Health Enviromonitor
3 Perception 16 Vantage Pro, Vantage Pro 2
Example:
>"WRD"<0x12><0x4D><LF>
<<ACK><16>
"RXCHECK"
It sends the Console Diagnostics report. The following values are sent on one line as a text
string: total packets received, total packets missed, number of resynchronizations, the largest
number of packets received in a row., and the number of CRC errors detected.