EasyManuals Logo

DAVIS Vantage Pro2 Quick Reference Guide

DAVIS Vantage Pro2
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
LAMPS BAR
Press 2
ND
& LAMPS to toggle between:
Backlight on.
Backlight off.
If the console is running on AC power:
The backlight will remain on until you turn it off.
If the console is running on battery power,
The backlight will remain on as long as you continue pressing
various
keys or a ticker tape message is scrolling across the screen. It will
automatically turn off if you do not press a key within ten seconds.
The backlight will not come on when battery power is low.
Press BAR to select:
Barometric Pressure (0.00 in, 0.0 mm, 0.0 hPa, 0.0 mb)
Press 2
ND
& UNITS to change unit of measure.
To correct for elevation change:
1. Press and hold DONE and then press () to enter the setup screen.
2. Press DONE nine times or until you see ENTER ELEVATION.
3. Press 2
ND
& UNITS to change from feet to meters, if desired.
4. Press ( + ) or ( ) to change the flashing digit. Press ( < ) or ( > ) to
move between fields.
5. Press and hold DONE to return to the current weather screen.
Barometric Trend Arrow shows change over the last three hours:
Increase of 0.06" Hg (2.0 hPa, 1.5 mm Hg) or more.
Increase of 0.02" Hg (0.7 hPa, 0.5 mm Hg) or more.
Change of less than 0.02" Hg (0.7 hPa, 0.5 mm Hg).
Decrease of 0.02" Hg (0.7 hPa, 0.5 mm Hg) or more.
Decrease of 0.06" Hg (2.0 hPa, 1.5 mm Hg) or more.
22 11

Other manuals for DAVIS Vantage Pro2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DAVIS Vantage Pro2 and is the answer not in the manual?

DAVIS Vantage Pro2 Specifications

General IconGeneral
Update Interval2.5 seconds
Temperature Accuracy±1°F (±0.5°C)
Barometric Pressure Range16.00 to 32.50 inHg (540 to 1100 hPa)
Rain Collector TypeTipping bucket
Wind Speed Range0 to 200 mph (0 to 322 km/h)
Wind Speed Accuracy±2 mph (±3 km/h) or ±5%, whichever is greater
Wind Direction Resolution
Wind Direction Accuracy±3°
Solar Radiation Range0 to 1800 W/m²
Solar Radiation Sensor Accuracy±5%
UV Index Range0 to 16
UV Index Accuracy±5%
Wireless Transmission RangeUp to 1000 ft (300 m)
Temperature Range-40°F to +150°F (-40°C to +65°C)
Humidity Range0 to 100%
Humidity Accuracy±3%
Rain Collector Resolution0.01 in (0.2 mm)
Rain Measurement Accuracy±4%
Wind Direction Range0 to 360°
Power SupplySolar powered with battery backup