EasyManua.ls Logo

dbx 363X - Front Panel Controls; Threshold Control and Open LED

dbx 363X
34 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Front
Pandl
dbx
363X
Figure
1:
Front
Panel
A.
STEREO
COUPLE
switch
and
LED.
Depress
this
switch
to
activate
Stereo-coupling
(CH
1 MASTER,
CH
2
SLAVE).
The
LED
next
to the
STEREO
COUPLE
button
turns
on
when
the
363X
is
actively
stereo
coupled.
In
Stereo
Couple
mode,
the
THRESHOLD,
HOLD
and
RELEASE
controls on
Channel
2
have
no
effect
on the gating
action.
The
Channel
2 OPEN,
HOLD
and
RELEASE
LEDs
track
with
Channel
1
meters.
B.
THRESHOLD
control
and
OPEN
LED
(CH
1 and
CH
2)
Adjusting
this
control
sets
the
level
at which
the
gate will
open
with
regard
to the
Input
level.
The
THRESHOLD
control
is
calibrated
in
dB
from
-60
to
+20dB,
to
provide
an
80dB
oper-
ating
range.
The
green
OPEN
LED
located
above
the
THRESHOLD
control
turns
on
whenever
the
in-
put
signal
(or
Key
Input
signal)
rises
above
the
set
THRESHOLD
level.

Related product manuals