Do you have a question about the dbx 266xs and is the answer not in the manual?
Type | Compressor/Gate |
---|---|
Number of Channels | 2 |
Dynamic Range | > 114 dB, unweighted |
Input Connectors | XLR and 1/4" TRS |
Input Type | Electronically balanced/unbalanced, RF filtered |
Output Connectors | XLR and 1/4" TRS |
Output Type | Electronically balanced/unbalanced, RF filtered |
IMD | <0.1% SMPTE |
CMRR | > 40 dB, typically > 55 dB at 1 kHz |
Compressor Threshold Range | -40 dBu to +20 dBu |
Compressor Ratio | 1:1 to Infinity:1 |
Controls | Threshold, Ratio, Attack, Release, Output |
Frequency Response | 20Hz - 20kHz |
Maximum Input Level | +22dBu |
Maximum Output Level | +21 dBu balanced/unbalanced |
Dimensions | 1.75" x 5.75" x 19" |
Weight | 5.5 lbs |
Side Chain Insert | 1/4" TRS |
Noise | <-90dBu |
THD+N | <0.1% @ +4dBu, 1kHz |
Crosstalk | <-80dB, 20Hz - 20kHz |
Interchannel Crosstalk | <-80dB, 20Hz - 20kHz |
Power Consumption | 15W |
Operating Voltage | 100-240 VAC, 50/60 Hz |
Operating Temperature | 32°F to 113°F (0°C to 45°C) |
Expander/Gate Threshold Range | +10dB |
Expander/Gate Ratio | 1:1 |
Expander/Gate Release Time | 50ms to 2s |
Expander/Gate Attack Time | 100 μs |
Details the unit's compliance with safety and electromagnetic compatibility standards and directives.
Provides essential safety warnings regarding the use of mains plugs, fuses, and socket connections in the UK.
Lists product specifications, safety standards (IEC 60065), EMC standards (EN 55022), and compliance directives.
Lists and explains typical uses for the compressor function, such as drum fattening and vocal smoothing.
Lists and explains common uses for the gate function, including noise reduction and instrument envelope shaping.
Provides details for obtaining technical support, warranty registration, and factory service procedures.
Outlines the terms of the product's limited two-year warranty, including registration and service requirements.
Details the rear panel connectors for power, audio inputs/outputs, and sidechain inserts.
Explains the function of key front panel controls like STEREO COUPLE, BYPASS, GAIN REDUCTION meter, and OUTPUT GAIN.
Details the function of the Compressor THRESHOLD, RATIO, ATTACK, and RELEASE controls and their associated LEDs.
Details the function of the Expander/Gate THRESHOLD, RATIO, and AUTO switch controls and their associated LEDs.
Explains how to adjust the Expander/Gate RATIO for downward expansion or hard gating effects.
Provides instructions for connecting the unit to various audio equipment and power sources.
Outlines how to get technical assistance, including serial number requirements and shipping instructions for service.
Encourages users to complete and return the registration card for feedback and warranty validation.
Provides detailed technical data including input/output levels, frequency response, distortion, noise, and physical dimensions.
Illustrates the internal signal flow and functional blocks of the dbx 266xs compressor/gate.